Belden 7916AP 877, Coax DBS Cable 18 AWG FFEP FLRST Natural

Description
Belden 7916AP 877 is a Series 6 broadband coax cable for high-performance CATV, RF drop cable, Direct Broadcast Satellite (DBS), and Over-The-Air (OTA) antenna runs. It features an 18 AWG solid BC - Bare Copper conductor, FEP - Fluorinated Ethylene Propylene (Foam) insulation, and a Quad Shield (F/B+F/B) construction to help maintain signal integrity. The PVC - Polyvinyl Chloride Flamarrest® jacket is CMP Plenum rated for indoor plenum installations where fire performance is required. Electrical performance includes 75 Ohm nominal impedance, published return loss through 3000 MHz, and nominal attenuation data through 1000 MHz.
Belden 7916AP 877 Key Features
- Series 6 broadband coax cable with RG 6 coax type and coaxial construction.
- 18 AWG solid BC - Bare Copper conductor for consistent center-conductor performance.
- FEP - Fluorinated Ethylene Propylene (Foam) insulation with FFEP-foamed (cellular) dielectric material.
- Quad Shield (F/B+F/B) design with tape and braid layers to help support signal integrity.
- PVC - Polyvinyl Chloride Flamarrest® jacket with plenum fire rating and CMP designation.
- 75 Ohm nominal characteristic impedance with published attenuation and return loss data.
Belden 7916AP 877 Applications
- Use in broadband installations that need a Series 6 coax cable to carry RF signals across a run.
- Support Cable Television (CATV) distribution runs that require consistent coax performance.
- Connect RF drop cable links between distribution points and end equipment.
- Run Direct Broadcast Satellite (DBS) signals in indoor environments.
- Connect Over-The-Air (OTA) antennas to receiving equipment using coax.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Overall cable diameter (nominal) | 0.248 in (6.30 mm) |
| Conductor nominal diameter | 0.040 in |
| Nom. insulation diameter | 0.170 in (4.32 mm) |
| Jacket Color | Natural |
| Insulation color code | White |
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
| Shield layer 2 | Braid, Aluminum, 60% |
| Shield layer 3 | Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% |
| Shield layer 4 | Braid, Aluminum, 40% |
| Flooded | No, not flooded over braid |
| Outdoor | No, not outdoor grade material |
| Bulk cable weight | 39 lbs/1000ft |
| Nom. velocity of prop. | 83% |
| Nom. capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. outer shield DCR | 4.8 Ohm/1000ft (16 Ohm/km) |
| Return loss | 5 - 1000 MHz: 20 dB; 1000 - 2250 MHz: 15 dB; 2250 - 3000 MHz: 10 dB |
| Attenuation (Nominal) | 1 MHz: 0.3 dB/100ft; 10 MHz: 0.7 dB/100ft; 50 MHz: 1.6 dB/100ft; 100 MHz: 2.1 dB/100ft; 200 MHz: 2.9 dB/100ft; 400 MHz: 4.3 dB/100ft; 700 MHz: 6.1 dB/100ft; 750 MHz: 6.4 dB/100ft; 900 MHz: 7.1 dB/100ft; 1000 MHz: 8.2 dB/100ft |
| UL temperature | 75°C |
| Operating | -20°C to +75°C |
| Installation min. bend radius | 2.5 in (64 mm) |
| Max Pull Tension | 137 lbs (62.1 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| UL Voltage Rating | 300 V (CMP) |
| Flammability / reaction to fire | NFPA 262 |
| CEC / C(UL) compliance | CMP |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 7916A |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 7916AP 877250, 7916AP 877500, 7916AP 8771000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.