Belden 8135 060, Multi Conductor Computer Cable 5 Pair 28 AWG PVC

Description
Belden 8135 060 is a 5-pair computer EIA RS-232/485 cable for data and control signaling in industrial and commercial systems. It uses 28 AWG stranded (7x36) tinned copper conductors with PE - Polyethylene (Foam) insulation and a PVC - Polyvinyl Chloride jacket. For noise rejection, it includes a tape shield with 100% coverage plus a tinned copper (TC) braid with 65% coverage, along with a 28 AWG (7x36) TC drainwire. Key electrical ratings include UL Voltage Rating: 30 V (UL AWM 2919) and UL temperature: 80°C (UL AWM 2919).
Belden 8135 060 Key Features
- 5 pairs support multi-channel data and control signaling in industrial and commercial systems.
- 28 AWG stranded (7x36) tinned copper conductors support reliable signal transmission.
- PE - Polyethylene (Foam) insulation with a defined color code: White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe, White/Green Stripe & Green/White Stripe, White/Brown Stripe & Brown/White Stripe, White/Gray Stripe & Gray/White Stripe.
- Dual shielding design: Tape (Bi-Laminate (Alum+Poly)) with 100% coverage plus a tinned copper (TC) braid with 65% coverage.
- 28 AWG (7x36) TC drainwire supports termination.
- PVC - Polyvinyl Chloride jacket in Chrome provides durable outer protection.
- UL Voltage Rating: 30 V (UL AWM 2919).
- UL temperature: 80°C (UL AWM 2919) with Operating: -30°C to +80°C.
- Compliance and markings include CL2, AWM 2919, UL1685 UL Loading, IEC 60332-1-2, CPR Euroclass: Eca, EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), UKCA Mark, and China RoHS II (GB/T 26572-2011).
Belden 8135 060 Applications
- Use for RS-232 extended distance applications where consistent data signaling is needed over longer runs.
- Support RS-485 applications for data and control signaling in industrial and commercial systems.
- Fit computer communications links that require stable, noise-resistant signal performance.
- Handle low voltage analog signals (4-20ma, 0-10v, ...) in control and monitoring circuits.
- Work with low voltage digital control (24v, …) for control signaling and device interfacing.
- Suit line level audio connections where signal integrity is important.
- Serve panel wiring needs to organize and route signal and control connections within enclosures.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.0145 in (0.368 mm) |
| Jacket thickness (nom.) | 0.035 in (0.89 mm) |
| Overall cable diameter (nom.) | 0.288 in (7.32 mm) |
| Bulk cable weight | 36 lbs/1000ft (54 kg/km) |
| Nom. conductor DCR | 65 Ohm/1000ft (210 Ohm/km) |
| Nom. outer shield DCR | 4.2 Ohm/1000ft (14 Ohm/km) |
| Nom. capacitance cond-to-cond | 11 pF/ft (36 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 20 pF/ft (66 pF/m) |
| Nom. characteristic impedence | 120 Ohm |
| Nom. velocity of prop. | 78% |
| Max. current | 0.9 Amps per Conductor at 25ºC |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 8135 060100, 8135 060250, 8135 060500, 8135 0601000 |
| Priced Per | FT |