Belden 8167 060, Multi Conductor Computer Cable 7 FS PR 24 AWG PVC

SKU:Belden 8167 060
● In stock
Description
Belden 8167 060 is a multi-pair 24 AWG computer and digital audio cable designed for RS-232 extended distance and RS-422 applications, computer communications, and low-voltage analog and digital control signals. It is built with 7 twisted pairs of 24 AWG stranded (7x32) TC - Tinned Copper conductors and a PVC - Polyvinyl Chloride jacket in Chrome. For noise rejection, each pair is individually shielded with tape, bi-laminate (Alum+Poly) at 100% coverage, and the cable also includes an overall 100% tape shield plus a tinned copper braid at 65% coverage. It carries UL voltage rating: 300 V (CM), 300 V (UL AWM 2493) and is rated for indoor environmental suitability.
Belden 8167 060 Key Features
- 7 twisted pairs support multi-pair signal routing in one cable.
- 24 AWG stranded (7x32) TC - Tinned Copper conductors provide flexibility with tinned copper construction.
- Individual pair shielding uses tape, bi-laminate (Alum+Poly), 100% coverage; each pair includes Z-Fold® Foil-in for pair-level noise rejection.
- Overall shielding combines tape, bi-laminate (Alum+Poly), 100% coverage with a tinned copper (TC) braid at 65% coverage.
- PVC - Polyvinyl Chloride jacket with jacket color: Chrome.
- NEC / UL compliance: Article 800, CM and AWM compliance: AWM 2493.
Belden 8167 060 Applications
- Supports RS-232 extended distance & RS-422 applications where multi-pair signal cabling is required.
- Enables computer communications in installations that need a multi-pair communications cable.
- Handles low voltage analog signals (4-20ma, 0-10v, ...) for control and instrumentation signal runs.
- Works with low voltage digital control (24v, …) in control and automation wiring.
- Distributes digital audio signals where a multi-pair format is needed.
- Fits panel wiring needs in indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PE - Polyethylene (Foam) |
| Insulation nominal thickness | 0.019 in (0.48 mm) |
| Color Code | Black & Red, Black & White, Black & Green, Black & Blue, Black & Yellow, Black & Brown, Black & Orange |
| Pair drainwire | 24 AWG (7x32) TC |
| Jacket nominal thickness | 0.048 in (1.2 mm) |
| Overall cable diameter (nominal) | 0.446 in (11.3 mm) |
| Bulk cable weight | 95 lbs/1000ft (140 kg/km) |
| Nominal conductor DCR | 24 Ohm/1000ft (79 Ohm/km) |
| Nominal capacitance (Cond-to-Cond) | 12.5 pF/ft (41.0 pF/m) |
| Nominal capacitance (Cond-to-other (conds + Shield)) | 22 pF/ft (72 pF/m) |
| Nominal characteristic impedence | 100 Ohm |
| Nominal velocity of prop. | 78% |
| Max. current | 1.6 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 2.8 Ohm/1000ft (9.2 Ohm/km) |
| UL Voltage Rating | 300 V (CM), 300 V (UL AWM 2493) |
| Operating temperature | -40°C to +60°C |
| UL temperature | 60°C (UL AWM 2493) |
| Bend radius (stationary min.) | 4.5 in (110 mm) |
| Bend radius (installation min.) | 4.5 in (110 mm) |
| Max Pull Tension | 160 lbs (73 kg) |
| Environmental suitability | Indoor |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL1685 UL Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 8167 060100, 8167 060250, 8167 060500, 8167 0601000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.