Belden 8218 010 is a 75 Ohm miniature coax (Mini 59) designed for reliable signal transmission in indoor, general-purpose installations. It features a 27 AWG stranded (7x35) BCCS - Bare Copper Covered Steel conductor, PE - Polyethylene insulation, and a Tinned Copper (TC) braid shield with 95% coverage. A black PVC - Polyvinyl Chloride jacket supports durable handling, and the cable is rated AWM 1354 (30 V 60°C) with an operating temperature range of -40°C to +60°C.
Belden 8218 010 Key Features
- 75 Ohm miniature coax (Mini 59) construction for reliable signal transmission in indoor, general-purpose installations.
- 27 AWG stranded (7x35) BCCS - Bare Copper Covered Steel conductor for compact coax builds.
- Tinned Copper (TC) braid shield with 95% coverage to support EMI protection.
- Black PVC - Polyvinyl Chloride jacket for durable handling.
- AWM 1354 (30 V 60°C) rating with an operating temperature range of -40°C to +60°C.
Belden 8218 010 Applications
- Use it for indoor, general-purpose coax runs where reliable signal transmission is required.
- Choose it when a miniature coax format is needed in indoor environments (Not Riser or Plenum).
- Select it for builds where a braided shield is used to help manage EMI in the installation environment.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Coax Type | Coaxial |
| Number of coax | 1 |
| Number of Conductors | 1 |
| Conductor nominal diameter | 0.017 in |
| Insulation Diameter | 0.1 in |
| Shield Type | Braid |
| Jacket diameter | 0.15 in |
| Nom. capacitance (Conductor to Shield) | 20.5 pF/ft |
| Nominal inductance | 0.115 µH/ft |
| Nominal delay | 1.54 ns/ft |
| Nominal velocity of propagation (VP) [%] | 66% |
| Nominal conductor DCR | 120 Ohm/1000ft |
| Nominal outer shield DCR | 5.7 Ohm/1000ft |
| Non-UL voltage rating | 1700 V RMS |
| UL Voltage Rating | 30 V RMS |
| Insertion loss @ 1 MHz | 1.2 dB/100ft |
| Insertion loss @ 10 MHz | 2.4 dB/100ft |
| Insertion loss @ 50 MHz | 4.2 dB/100ft |
| Insertion loss @ 100 MHz | 5.7 dB/100ft |
| Insertion loss @ 200 MHz | 8.3 dB/100ft |
| Insertion loss @ 400 MHz | 12.1 dB/100ft |
| Insertion loss @ 700 MHz | 16.5 dB/100ft |
| Insertion loss @ 900 MHz | 19 dB/100ft |
| Insertion loss @ 1000 MHz | 20 dB/100ft |
| Bulk cable weight | 14 lbs/1000ft |
| Max recommended pulling tension | 32 lbs |
| Minimum minor axis bend radius | 1.5 in |
| CPR Euroclass | Fca |
| Environmental space | Indoor (Not Riser or Plenum) |
| Plenum (Y/N) | No |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | No |
| MII Order #39 (China RoHS) | Yes |
| Priced Per | FT |