Belden 82241 877, Coax RG 59 U 23 AWG FEP 75 Ohm FLMRST

Description
Belden 82241 877 is an RG 59 coaxial cable for indoor plenum installations, featuring a 23 AWG solid 0.023 in BCCS - Bare Copper Covered Steel conductor and FEP - Fluorinated Ethylene Propylene insulation. It uses a Bare Copper (BC) braid shield with 95% coverage and a PVC - Polyvinyl Chloride Flamarrest® jacket in Natural. This coax is rated 75 Ohm and meets CMP requirements with UL flammability: NFPA 262.
Belden 82241 877 Key Features
- RG 59 coaxial construction with 1 coax and 1 conductor.
- 23 AWG solid conductor with 0.023 in nominal diameter, using BCCS - Bare Copper Covered Steel.
- FEP - Fluorinated Ethylene Propylene insulation with 0.134 in nominal diameter.
- Bare Copper (BC) braid shield with 95% coverage.
- PVC - Polyvinyl Chloride jacket with Flamarrest® material trade name, Natural color, and 0.19 in nominal diameter.
- Indoor - Plenum rated with Plenum (Y/N): Yes, NEC/(UL) compliance: CMP, CEC/C(UL) compliance: CMP, and UL flammability: NFPA 262.
- Nominal characteristic impedance: 75 Ohm.
Belden 82241 877 Applications
- Use in indoor plenum installations requiring CMP and UL flammability: NFPA 262 compliance.
- Support 75 Ohm signal transmission for video and RF distribution applications.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Nom. capacitance (Conductor to Shield) | 19.5 pF/ft |
| Nominal inductance | 0.126 µH/ft |
| Nominal delay | 1.45 ns/ft |
| Nominal velocity of propagation (VP) [%] | 70% |
| Nominal conductor DCR | 49 Ohm/1000ft |
| Nominal outer shield DCR | 2.6 Ohm/1000ft |
| Non-UL voltage rating | 1700 V RMS |
| UL Voltage Rating | 300 V RMS |
| Insertion loss @ 1 MHz | 0.5 dB/100ft |
| Insertion loss @ 10 MHz | 1 dB/100ft |
| Insertion loss @ 50 MHz | 2.3 dB/100ft |
| Insertion loss @ 100 MHz | 3.3 dB/100ft |
| Insertion loss @ 200 MHz | 5.2 dB/100ft |
| Insertion loss @ 400 MHz | 8.4 dB/100ft |
| Insertion loss @ 700 MHz | 11.6 dB/100ft |
| Insertion loss @ 900 MHz | 13.8 dB/100ft |
| Insertion loss @ 1000 MHz | 14.8 dB/100ft |
| Non-UL temp rating | 75°C |
| UL Temperature Rating | 60°C |
| Operating Temperature Range | -20°C To +75°C |
| Bulk cable weight | 34 lbs/1000ft |
| Maximum recommended pulling tension | 62 lbs |
| Minimum minor axis bend radius | 2 in |
| Environmental programs | EU Directive 2000/53/EC (ELV): Yes; EU Directive 2003/11/EC (BFR): Yes; EU Directive 2011/65/EU (RoHS 2): Yes; EU Directive 2012/19/EU (WEEE): Yes; EU Directive 2015/863/EU (RoHS 2 amendment): Yes; EU Directive compliance: EU Directive 2003/11/EC (BFR); EU CE mark: No; MII Order #39 (China RoHS): Yes |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 82241 877100; 82241 877250; 82241 877500; 82241 877U500 UPC 612825196495; 82241 8771000 UPC 612825196457 |