Belden 82503 877, Multi Conductor Computer Cable 3 Pair 24 AWG FEP

SKU:Belden 82503 877
● In stock
Description
Belden 82503 877 is a 3-pair, 24 AWG computer EIA RS-232 cable designed for reliable signal transmission in indoor plenum environments. It features 24 AWG stranded (7x32) tinned copper conductors with FEP insulation, plus an overall Beldfoil® shield (100% coverage) and a 24 AWG stranded tinned copper drain wire to help reduce noise. The Flamarrest® jacket and CMP plenum rating support use in demanding building spaces where fire performance is critical.
Belden 82503 877 Key Features
- 3-pair, 24 AWG computer EIA RS-232 cable construction for signal transmission in indoor plenum environments.
- 24 AWG stranded (7x32) TC - tinned copper conductors with FEP - fluorinated ethylene propylene insulation.
- Overall Beldfoil® shield (100% coverage) with bi-laminate (Alum+Poly) tape and a 24 AWG (7x32) TC drainwire.
- Flamarrest® PVC - polyvinyl chloride jacket with CMP plenum rating.
Belden 82503 877 Applications
- Meets indoor plenum applications where CMP plenum cable is required.
- Designed for RS-232 applications in control and communication links.
- Fits computer communications setups that rely on consistent signal transmission.
- Handles low voltage analog signals (4-20ma, 0-10v, ...) in instrumentation and control circuits.
- Supports low voltage digital control (24v, …) connections in automation and control panels.
- Suitable for line level audio signal runs.
- Commonly used for panel wiring where organized multi-pair signal routing is needed.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.006 in (0.15 mm) |
| Insulation diameter (nom.) | 0.036 in (0.91 mm) |
| Color Code | Black & Red, Black & White, Black & Green |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.171 in (4.34 mm) |
| Jacket Color | Natural |
| Bulk cable weight | 18 lbs/1000ft |
| Nom. conductor DCR | 24.1 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 25 pF/ft (82 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 45 pF/ft (150 pF/m) |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Max. current | 1.5 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 15 Ohm/1000ft (49 Ohm/km) |
| UL Voltage Rating | 300 V (CMP) |
| UL temperature | 60°C |
| Operating | 0°C to +60°C |
| Stationary min. bend radius | 1.7 in (43 mm) |
| Installation min. bend radius | 1.7 in (43 mm) |
| Max Pull Tension | 39 lbs (18 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 82503 877100; 82503 877250; 82503 877500; 82503 8771000 UPC 612825197195 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.