AttributeValue
Cable typeMil-Spec coax
Coax constructionCoaxial
RG type213
Coax TypeRG 213
Overall cable diameter (nominal)0.405 in (10.3 mm)
FloodedNo NOT FLOODED OVER BRAID
Conductor nominal diameter0.089 in
Conductor MaterialBC - Bare Copper
Conductor TypeStranded conductor
Dielectric MaterialPE-POLYETHYLENE (Solid)
Insulation diameter (nominal)0.285 in (7.24 mm)
Color CodeWhite
Outer shield typeBraid
Shield TypeBraid only
Shield MaterialBare Copper (BC)
Jacket MaterialPVC - Polyvinyl Chloride (Non-Contaminating)
Jacket diameter (nominal)0.405 in (10.3 mm)
OutdoorYes IS OUTDOOR GRADE MATERIAL
Bulk cable weight104 lbs/1000ft
Nom. conductor DCR1.7 Ohm/1000ft
Nom. outer shield DCR1.2 Ohm/1000ft (3.9 Ohm/km)
Nom. capacitance (Cond-to-Shield)30.8 pF/ft (101 pF/m)
Nom. velocity of propagation66%
UL Voltage Rating300 V (CMX), 30 V (UL AWM 1354)
Voltage Rating3700 V (Mil-Spec)
Attenuation @ 1 MHz0.17 dB/100ft
Attenuation @ 10 MHz0.55 dB/100ft
Attenuation @ 50 MHz1.3 dB/100ft
Attenuation @ 100 MHz1.9 dB/100ft
Attenuation @ 200 MHz2.7 dB/100ft
Attenuation @ 400 MHz4.1 dB/100ft
Attenuation @ 700 MHz6.5 dB/100ft
Attenuation @ 900 MHz7.6 dB/100ft
Attenuation @ 1000 MHz8.0 dB/100ft
Attenuation @ 4000 MHz21.5 dB/100ft
Power rating @ 1 MHz9,295 W
Power rating @ 10 MHz2,761 W
Power rating @ 50 MHz1,122 W
Power rating @ 100 MHz748 W
Power rating @ 200 MHz494 W
Power rating @ 400 MHz326 W
Power rating @ 700 MHz235 W
Power rating @ 900 MHz205 W
Power rating @ 1,000 MHz194 W
Power rating @ 4,000 MHz110 W
UL temperature60°C (UL AWM 1354)
Operating temperature-40°C to +80°C
Installation min. bend radius4 in (100 mm)
Max Pull Tension184 lbs (83.5 kg)
Environmental suitabilityIndoor (Not Riser or Plenum), Indoor
NEC / UL complianceCMX
CEC / C(UL) complianceCMX
AWM complianceAWM 1354
Flammability / reaction to fireVW-1
CPR complianceCPR Euroclass: Eca
Fire ratingGeneral Purpose (CM, CMG, CMX)
Military complianceCommercial, non-QPL product (M17/163-00001)
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Item TypeBelden Coaxial Cable
Other Part Numbers8267 010100; 8267 010250; 8267 010500; 8267 0101000
Priced PerFT

Documents

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.