Belden 8268 010, M17 164 00001 50 Ohm Coax Black

Description
Belden 8268 010 is a 50 Ohm Mil-Spec coax built to RG-214 and M17/164-00001 for reliable RF performance in demanding installations. It features a 13 AWG (7x21) SC - Silvered Copper conductor with PE - Polyethylene insulation and a double braid shield with 95% coverage per layer. The PVC - Polyvinyl Chloride (Non-Contaminating) jacket in Black is listed for Indoor (Not Riser or Plenum) use and Indoor, Aerial - Black only, When supported by messenger Wire.
Belden 8268 010 Key Features
- Built to RG-214 and M17/164-00001 as a 50 Ohm Mil-Spec coax.
- Uses a 13 AWG (7x21) SC - Silvered Copper conductor with PE - Polyethylene insulation.
- Double outer shield: braid, Silvered Copper (SC), with 95% coverage on layer 1 and 95% coverage on layer 2.
- PVC - Polyvinyl Chloride (Non-Contaminating) jacket in Black for Indoor (Not Riser or Plenum) use and Indoor, Aerial - Black only, When supported by messenger Wire.
Belden 8268 010 Applications
- Commonly used in high frequency microwave and satellite installations where consistent RF signal delivery is required.
- Supports point-to-point and point-to-multipoint wireless antenna communication links in demanding installation environments.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Nom. conductor diameter | 0.089 in |
| Nom. insulation diameter | 0.285 in (7.24 mm) |
| Insulation color code | White |
| Overall cable diameter (nominal) | 0.425 in (10.8 mm) |
| Bulk cable weight | 131 lbs/1000ft |
| Nom. velocity of prop. | 66% |
| Nom. capacitance (Cond-to-Shield) | 30.8 pF/ft (101 pF/m) |
| Nom. conductor DCR | 1.7 Ohm/1000ft |
| Nom. outer shield DCR | 0.7 Ohm/1000ft (2.3 Ohm/km) |
| UL Voltage Rating | 300 V (CMX), 30 V (UL AWM 1354) |
| Voltage Rating | 3700 V (Mil-Spec) |
| Attenuation (nominal) 1 MHz | 0.17 dB/100ft |
| Attenuation (nominal) 10 MHz | 0.55 dB/100ft |
| Attenuation (nominal) 50 MHz | 1.3 dB/100ft |
| Attenuation (nominal) 100 MHz | 1.9 dB/100ft |
| Attenuation (nominal) 200 MHz | 2.7 dB/100ft |
| Attenuation (nominal) 400 MHz | 4.1 dB/100ft |
| Attenuation (nominal) 700 MHz | 6.5 dB/100ft |
| Attenuation (nominal) 900 MHz | 7.6 dB/100ft |
| Attenuation (nominal) 1000 MHz | 8.0 dB/100ft |
| Attenuation (nominal) 4000 MHz | 20.0 dB/100ft |
| Power rating (max.) 50 MHz | 1,500 W |
| Power rating (Max.) 100 MHz | 907 W |
| Power rating (Max.) 200 MHz | 549 W |
| Power rating (Max.) 400 MHz | 332 W |
| Power rating (Max.) 700 MHz | 221 W |
| Power rating (max.) 900 MHz | 184 W |
| Power rating (Max.) @ 1,000 MHz | 171 W |
| Power rating (max.) 4,000 MHz | 62 W |
| UL temperature | 60°C (UL AWM 1354) |
| Operating temperature | -40°C to +80°C |
| Installation min. bend radius | 4.25 in (108 mm) |
| Max Pull Tension | 225 lbs (102 kg) |
| NEC / UL compliance | CMX |
| CEC / C(UL) compliance | CMX |
| AWM compliance | AWM 1354 |
| Flammability / reaction to fire | VW-1 |
| CPR compliance | CPR Euroclass: Eca |
| Military compliance | Commercial, non-QPL product (M17/164-00001) |
| Sustainability | CA Prop 65 |
| European directive compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 8268 010100; 8268 010250; 8268 010500; 8268 0101000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.