Belden 82761 877U, Multi Pair Cable 1C 22 AWG FEP Flamarrest Jacket, Natural Jacket

Description
Belden 82761 877U is a 1 pair, 22 AWG electronic cable designed for Indoor - Plenum, Indoor installations. It uses 22 AWG Stranded (7x30) TC - Tinned Copper conductors with FEP - Fluorinated Ethylene Propylene insulation and an Overall Beldfoil® Shield with 100% coverage plus a 22 AWG (7x30) TC drainwire. A PVC - Polyvinyl Chloride outer jacket in Natural supports CMP plenum requirements, with a UL Voltage Rating of 300 V (CMP) and a UL temperature rating of 75°C.
Belden 82761 877U Key Features
- 1 pair construction with 22 AWG conductors for low-voltage signal and control wiring.
- 22 AWG Stranded (7x30) TC - Tinned Copper conductors with FEP - Fluorinated Ethylene Propylene insulation.
- Overall Beldfoil® Shield (Tape, Bi-Laminate (Alum+Poly)) with 100% coverage and a 22 AWG (7x30) TC drainwire.
- PVC - Polyvinyl Chloride outer jacket with Natural jacket color.
- Environmental suitability: Indoor - Plenum, Indoor; NEC / UL compliance: Article 800, CMP; CEC / C(UL) compliance: CMP.
- Flammability / reaction to fire: NFPA 262, UL 910 (Plenum), FT6.
- UL Voltage Rating: 300 V (CMP); UL temperature: 75°C.
Belden 82761 877U Applications
- Designed for Indoor - Plenum applications where low-voltage signal wiring is required.
- Supports low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation-style signal paths.
- Handles low voltage digital control (24v, …) where consistent signal transmission is needed.
- Works well for line level audio connections in building and equipment wiring.
- Meets voice communications wiring needs where a shielded pair is used for signal paths.
- Commonly used for panel wiring to route low-voltage signals within control panels and enclosures.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 1 |
| Element type | pair(s) |
| Insulation thickness (nom.) | 0.007 in (0.18 mm) |
| Insulation diameter (nom.) | 0.042 in (1.1 mm) |
| Color Code | Black & Red |
| Outer jacket thickness (nom.) | 0.014 in (0.36 mm) |
| Outer jacket diameter (nom.) | 0.118 in (3.00 mm) |
| Overall cable diameter (nominal) | 0.118 in (3.00 mm) |
| Nom. conductor DCR | 15 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 42 Ohm |
| Nom. inductance | 0.16 µH/ft (0.52 µH/m) |
| Max. current | 2.8 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 18.2 Ohm/1000ft (59.7 Ohm/km) |
| Operating temperature | -20°C to +75°C |
| Bend radius (stationary min.) | 1.18 in (30.0 mm) |
| Bend radius (installation min.) | 1.18 in (30.0 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Bulk cable weight | 11 lbs/1000ft |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 8761 |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 82761 877U500 UPC 612825197775 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.