Belden 8279 010, Miniature Coax Cable 23 AWG Shielded Polyethylene, Black Jacket

Description
Belden 8279 010 is a miniature 75 Ohm coaxial cable with a 23 AWG stranded (7x32) .023 bare compacted copper conductor and a PE - Polyethylene jacket in black. It features PE - Polyethylene insulation and a tinned copper (TC) braid shield with 95% coverage for consistent signal transmission. Electrical characteristics include 21 pF/ft capacitance and 66% nominal velocity of propagation (VP). It is suitable for indoor and outdoor installations, including Outdoor - Direct Burial, and aerial runs when supported by messenger wire.
Belden 8279 010 Key Features
- Miniature 75 Ohm coaxial design (RG type: Mini 59; Series type: 59) for compact coax installations.
- 23 AWG stranded (7x32) .023 bare compacted copper conductor with PE - Polyethylene insulation.
- Tinned copper (TC) braid shield with 95% coverage for shielded coax performance.
- PE - Polyethylene outer jacket in black.
- Suitable for indoor use, outdoor use, Outdoor - Direct Burial, and aerial installation when supported by messenger wire.
Belden 8279 010 Applications
- Supports compact coaxial installations where a miniature 75 Ohm cable format is needed.
- Works well for indoor installation environments where shielded coax routing is required.
- Fits outdoor installation needs, including Outdoor - Direct Burial.
- Enables aerial runs when supported by messenger wire.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Number of coax | 1 |
| Number of Conductors | 1 |
| Flooded | No not flooded over braid |
| Conductor nominal diameter | 0.023 in |
| Insulation nominal diameter | 0.146 in |
| Outer jacket nominal diameter | 0.22 in |
| Bulk cable weight | 26 lbs/1000ft |
| Nom. capacitance (Conductor to Shield) | 21 pF/ft |
| Nominal inductance | 0.118 µH/ft |
| Nominal delay | 1.54 ns/ft |
| Nominal velocity of propagation (VP) [%] | 66% |
| Non-UL voltage rating | 2300 V RMS |
| Nominal conductor DCR | 19.1 Ohm/1000ft |
| Nominal outer shield DCR | 4.5 Ohm/1000ft |
| Return loss (5-216 MHz) | 27 dB |
| Return loss (217-850 MHz) | 21 dB |
| Insertion loss @ 1 MHz | 0.4 dB/100ft |
| Insertion loss (3.6 MHz) | 0.6 dB/100ft |
| Insertion loss @ 10 MHz | 1.2 dB/100ft |
| Insertion Loss (71.5 MHz) | 3.3 dB/100ft |
| Insertion Loss (135 MHz) | 4.7 dB/100ft |
| Insertion Loss (270 MHz) | 6.8 dB/100ft |
| Insertion Loss (360 MHz) | 8 dB/100ft |
| Insertion Loss (540 MHz) | 9.9 dB/100ft |
| Insertion Loss (720 MHz) | 11.6 dB/100ft |
| Insertion Loss (750 MHz) | 11.9 dB/100ft |
| Insertion loss @ 1000 MHz | 13.8 dB/100ft |
| Non-UL temp rating | 80°C |
| Operating Temperature Range | -55°C To +80°C |
| Maximum recommended pulling tension | 45 lbs |
| Minimum minor axis bend radius | 2.5 in |
| Plenum (Y/N) | No |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | No |
| MII Order #39 (China RoHS) | Yes |
| Footnote | C - CRATE REEL PUT-UP. |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 8279 010100; 8279 010250; 8279 010500 UPC 612825358077; 8279 0101000 UPC 612825355892 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.