Belden 8406 010, Multi Conductor 3C 24 AWG EPDM SBR Black

Description
Belden 8406 010 is a 3-conductor, 24 AWG stranded audio cable for low frequency microphone or musical instruments and balanced analog audio applications. It uses 24 AWG Stranded (45x40) TCA - Tinned Copper Alloy conductors with EPDM - Ethylene Propylene Diene Monomer insulation and an EPDM - Ethylene Propylene Diene Monomer jacket in Black. The shielding system includes a Textile (Conductive), 100% tape layer plus a Tinned Copper (TC), 60% braid layer for noise rejection. Key electrical and installation details include a UL Voltage Rating of 300 V RMS and an Indoor (Not Riser or Plenum) environmental space designation.
Belden 8406 010 Key Features
- 3 conductors with 24 AWG Stranded (45x40) construction for flexible handling.
- TCA - Tinned Copper Alloy conductors with EPDM - Ethylene Propylene Diene Monomer insulation.
- Shielded design with Textile (Conductive), 100% tape (Layer 1) plus Tinned Copper (TC), 60% braid (Layer 2).
- EPDM - Ethylene Propylene Diene Monomer jacket in Black with a cotton serve separator.
- UL Voltage Rating: 300 V RMS.
- Environmental Space: Indoor (Not Riser or Plenum); Fire Rating: General Purpose.
Belden 8406 010 Applications
- Supports low frequency microphone or musical instruments where dependable signal handling is needed.
- Works well in balanced analog audio applications where noise rejection is important.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor nominal diameter | 0.024 in |
| Insulation nominal diameter | 0.065 in |
| Insulation nominal wall thickness | 0.016 in |
| Overall nominal diameter | 0.223 in |
| Jacket nominal wall thickness | 0.025 in |
| Max Recommended Current | 2.2 Amps per Conductor at 25ºC |
| Nominal conductor DCR | 28.7 Ohm/1000ft |
| Nominal outer shield DCR | 11.38 Ohm/1000ft |
| Nom. capacitance conductor to conductor | 30 pF/ft |
| Nom. capacitance conductor to other conductor to shield | 55 pF/ft |
| Non-UL temp rating | 90°C |
| Operating Temperature Range | -40°C To +90°C |
| Bulk cable weight | 33 lbs/1000ft |
| Maximum recommended pulling tension | 67 lbs |
| Minimum minor axis bend radius | 2.25 in |
| Shield Type | Braid Shielded |
| Shield construction | Special construction |
| Suitability - indoor | Yes |
| Plenum (Y/N) | No |
| EU Directive 2011/65/EU (RoHS 2) | No |
| EU Directive 2015/863/EU (RoHS 2 amendment) | No |
| EU CE mark | No |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 8406 010100, 8406 010250, 8406 010500, 8406 0101000, UPC 612825206255 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.