Belden 8467 060, Multi Conductor Cable 7C 18 AWG PVC PVC, Chrome Jacket

SKU:Belden 8467 060
● In stock
Description
Belden 8467 060 is a 7-conductor 18 AWG multi-conductor cable with 19x30 stranded tinned copper conductors, PVC insulation, and a PVC outer jacket. It is designed for indoor use and is rated 300 V (CMG) and 300 V (UL AWM 2598). This cable features a chrome jacket and a nominal overall cable diameter of 0.309 in (7.85 mm). It meets Article 800, CMG, UL 1685 FT4 Loading, FT4, and IEC 60332-1-2 compliance requirements.
Belden 8467 060 Key Features
- 7-conductor 18 AWG construction for multi-conductor signal and control wiring.
- 19x30 stranded tinned copper conductors.
- PVC - Polyvinyl Chloride insulation and PVC - Polyvinyl Chloride outer jacket.
- Rated 300 V (CMG) and 300 V (UL AWM 2598).
- Designed for indoor use.
- Chrome jacket color with a nominal overall diameter of 0.309 in (7.85 mm).
- Compliance includes Article 800, CMG, UL 1685 FT4 Loading, FT4, and IEC 60332-1-2.
Belden 8467 060 Applications
- Supports low voltage analog signals (4-20ma, 0-10v, ...) in indoor signal wiring runs.
- Use it for low voltage control (24v, …) where multi-conductor control connections are needed.
- Works for line level audio connections in indoor installations.
- Suitable for voice communications wiring where multiple conductors are required.
- Commonly used for panel wiring to route signals and control connections within panels.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor Material | TC - Tinned Copper |
| Shield | No |
| Color Code | Black, White, Red, Green, Brown, Blue, Orange |
| Insulation thickness (nom.) | 0.018 in (0.46 mm) |
| Insulation diameter (nom.) | 0.080 in (2.0 mm) |
| Outer jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Nom. conductor DCR | 7.13 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 26 pF/ft (85 pF/m) |
| Max. current | 9.8 Amps per Conductor at 30ºC |
| Operating temperature | -20°C to +60°C |
| UL temperature | 60°C |
| Bend radius (stationary min.) | 3.1 in (79 mm) |
| Bend radius (installation min.) | 3.1 in (79 mm) |
| Max Pull Tension | 173 lbs (78.5 kg) |
| Bulk cable weight | 69 lbs/1000ft |
| CEC / C(UL) compliance | CMG |
| AWM compliance | AWM 2598 |
| CPR Euroclass | Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 8467 060100, 8467 060250, 8467 060500, 8467 0601000, UPC 612825208358 |
| Priced Per | FT |