Belden 8728 060, Multi Conductor Cable 2C 22 AWG SHPR PP PVC

SKU:Belden 8728 060
● In stock
Description
Belden 8728 060 is a 2 pairs, 22 AWG multi-conductor cable with a PVC - Polyvinyl Chloride jacket in Chrome and an overall Beldfoil® Shield (100% coverage). It uses 22 AWG Stranded (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation and is cabled in pairs. Electrical ratings include 300 V RMS (UL AWM Style 2717) and 80°C (UL AWM Style 2717), with an operating temperature of -20°C to +80°C. It is listed as NEC / UL compliance: Article 800, CM and CEC / C(UL) compliance: CM.
Belden 8728 060 Key Features
- 2 pairs construction with 22 AWG stranded conductors for multi-conductor signal wiring.
- 22 AWG Stranded (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation.
- Cabled in pairs with color code: Black & Red, White & Green.
- Overall Beldfoil® Shield (100% coverage) with 24 AWG Stranded TC drain wires for shield termination.
- PVC - Polyvinyl Chloride jacket in Chrome.
- UL voltage rating: 300 V RMS (UL AWM Style 2717).
- UL temperature: 80°C (UL AWM Style 2717) with operating temperature: -20°C to +80°C.
- NEC / UL compliance: Article 800, CM; CEC / C(UL) compliance: CM.
Belden 8728 060 Applications
- Use it for low voltage analog signals (4-20ma, 0-10v, ...) in control and communication circuits.
- Support low voltage digital control (24v, …) where consistent signal wiring is needed.
- Connect line level audio signals with this cable.
- Specify it for computer communication wiring where shielded signal cable is required.
- Install it for panel wiring in control and communication panels.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Nom. insulation diameter | 0.05 in (1.3 mm) |
| Inner shield | Tape, Bi-Laminate (Alum+Poly), 100%; Tape, Polyester, 100% |
| Outer shield | Tape, Bi-Laminate (Alum+Poly), 100% |
| Jacket nominal thickness | 0.028 in (0.71 mm) |
| Jacket nominal diameter | 0.215 in |
| Nom. conductor DCR | 17 Ohm/1000ft (56 Ohm/km) |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 62 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 50 Ohm |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 2.3 Amps per Conductor at 25ºC |
| Max Pull Tension | 36.4 lbs (16.5 kg) |
| Bulk cable weight | 28 lbs/1000ft (42 kg/km) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| Fire rating | General Purpose |
| Flammability / reaction to fire | UL1685 UL Loading, IEC 60332-1-2 |
| AWM compliance | AWM 2717 (300 V 80°C) |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 8728 060, 8728 060100, 8728 060250, 8728 060500, 8728 0601000, UPC 612825214687, UPC 612825214670, UPC 612825214649 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.