Belden 88105 008, 5C 24 AWG Shielded Cable SOLEF Gray

Description
Belden 88105 008 is a Computer EIA RS-232/422 Cable designed for extreme high temperature environments and reliable computer communication. It is built with 5-pair 24 AWG stranded (7x32) TC - Tinned Copper conductors, foam FEP - Fluorinated Ethylene Propylene (Foam) insulation, and an overall Beldfoil® Shield (100% coverage) with a 24 AWG stranded tinned copper drain wire. A PVDF - Polyvinylidene Fluoride jacket in Gray and plenum rated construction support indoor installations where fire performance and compliance are required.
Belden 88105 008 Key Features
- Supports computer communication with a Computer EIA RS-232/422 Cable design.
- Built for extreme high temperature environments with an operating range of -20°C to +150°C and a UL temperature of 150°C.
- Uses 5-pair 24 AWG stranded (7x32) TC - Tinned Copper conductors with foam FEP - Fluorinated Ethylene Propylene (Foam) insulation.
- Includes an overall Beldfoil® Shield (100% coverage) and a 24 AWG (7x32) TC drainwire for noise control.
- Finished with a PVDF - Polyvinylidene Fluoride jacket in Gray and a plenum rated fire rating for indoor installations.
- Rated UL Voltage Rating: 300 V (CMP).
Belden 88105 008 Applications
- Installs in extreme high temperature environments where dependable signal transmission is required.
- Extends RS-232 distance in applications that require longer communication runs.
- Applies to RS-422 applications for computer communication links.
- Supports computer communication systems that require consistent data transfer.
- Handles low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation wiring.
- Provides low voltage digital control (24v, …) in automation and control circuits.
- Works for line level audio connections where signal integrity is important.
- Commonly used for panel wiring to organize and connect internal control and signal circuits.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor DCR (nom.) | 28.8 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 12.95 pF/ft (42.49 pF/m) |
| Capacitance, Cond-to-other (nom.) | 23.3 pF/ft (76.4 pF/m) |
| Characteristic impedence (nom.) | 100 Ohm |
| Delay (nom.) | 1.3 ns/ft |
| Inductance (nom.) | 0.21 µH/ft (0.69 µH/m) |
| Velocity of prop. (nom.) | 78% |
| Max. current | 2.2 Amps per Conductor at 25ºC |
| Outer shield DCR (nom) | 14.43 Ohm/1000ft (47.34 Ohm/km) |
| Color Code | Western Electric Standard |
| Insulation thickness (nom.) | 0.015 in (0.38 mm) |
| Insulation diameter (nom.) | 0.054 in (1.4 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket thickness (nom.) | 0.014 in (0.36 mm) |
| Jacket diameter (nom.) | 0.267 in (6.78 mm) |
| Overall cable diameter (nominal) | 0.267 in (6.78 mm) |
| Bulk cable weight | 40 lbs/1000ft |
| Stationary min. bend radius | 2.7 in (69 mm) |
| Installation min. bend radius | 2.7 in (69 mm) |
| Max Pull Tension | 60 lbs (27 kg) |
| Environmental suitability | Indoor |
| Flammability / reaction to fire | NFPA 262 (UL910), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 88105 008100, 88105 008250, 88105 008500, 88105 0081000, UPC 612825216704 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?