Belden 88241 010, Coaxial Cable Bare Copper Braid 500’
Description
Belden 88241 010 is an RG type 59 coaxial cable designed for standard analog video runs requiring consistent 75 Ohm performance. It features a 23 AWG solid 0.023 in BCCS - Bare Copper Covered Steel conductor with FEP - Fluorinated Ethylene Propylene insulation, plus a Bare Copper (BC) braid shield with 95% coverage. This plenum-rated coax uses an FEP - Fluorinated Ethylene Propylene jacket in black and has an overall nominal diameter of 0.190 in (4.83 mm). It supports an operating temperature range of -70°C to +200°C and meets NFPA 262 and Article 800, CMP.
Belden 88241 010 Key Features
- RG type 59 coaxial cable for standard analog video runs requiring consistent 75 Ohm performance.
- 23 AWG solid 0.023 in BCCS - Bare Copper Covered Steel conductor with FEP - Fluorinated Ethylene Propylene insulation.
- Bare Copper (BC) braid shield with 95% coverage to support signal integrity.
- Plenum-rated FEP - Fluorinated Ethylene Propylene jacket in black with a 0.190 in (4.83 mm) overall nominal diameter.
- Operating temperature: -70°C to +200°C.
- Compliance highlights: NFPA 262; Article 800, CMP.
Belden 88241 010 Applications
- Use it for standard analog video runs where consistent 75 Ohm performance is required.
- Install it in Indoor/Outdoor, Indoor, Outdoor, and Burial environments.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 1 |
| Insulation nominal diameter | 0.132 in (3.35 mm) |
| Color Code | Clear |
| Outer shield type | Braid |
| Bulk cable weight | 37 lbs/1000ft (55 kg/km) |
| Non-Plenum number | 8241 |
| Nom. velocity of prop. | 70% |
| Nom. capacitance (Cond-to-Shield) | 19.5 pF/ft (64.0 pF/m) |
| Nom. conductor DCR | 49 Ohm/1000ft (160 Ohm/km) |
| Nom. outer shield DCR | 2.6 Ohm/1000ft (8.5 Ohm/km) |
| UL Voltage Rating | 300 V RMS |
| Voltage Rating | 1700 V RMS |
| Attenuation (nominal) 1 MHz | 0.5 dB/100ft |
| Attenuation (nominal) 10 MHz | 1 dB/100ft |
| Attenuation (nominal) 50 MHz | 2.3 dB/100ft |
| Attenuation (nominal) 100 MHz | 3.3 dB/100ft |
| Attenuation (nominal) 200 MHz | 5.2 dB/100ft |
| Attenuation (nominal) 400 MHz | 8.4 dB/100ft |
| Attenuation (nominal) 700 MHz | 11.6 dB/100ft |
| Attenuation (nominal) 900 MHz | 13.8 dB/100ft |
| Attenuation (nominal) 1000 MHz | 14.8 dB/100ft |
| UL temperature | 200°C |
| Stationary min. bend radius | 1.9 in (48 mm) |
| Installation min. bend radius | 1.9 in (48 mm) |
| Max Pull Tension | 70 lbs (32 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Burial |
| Flammability / reaction to fire | NFPA 262, FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 88241 010100, 88241 010250, 88241 010500, 88241 0101000, UPC 612825216933 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.