Belden 88770 002, Multi Conductor Cable 3C 18 AWG FEP Jacket, Red Jacket

SKU:Belden 88770 002
● In stock
Description
Belden 88770 002 is a 3-conductor 18 AWG electronic multi conductor cable with FEP insulation and a FEP outer jacket in red. It uses 3 x 18 AWG (19x30) TC - Tinned Copper conductors and an overall Beldfoil® tape shield with 100% coverage plus a 20 AWG (19x32) TC drainwire. This cable is rated 300 V (CMP) with a UL temperature rating of 150°C and an operating temperature range of -20°C to +150°C. It meets NEC / UL compliance: Article 800, CMP and is tested to NFPA 262, UL 910 (Plenum), and IEC 60332-1-2.
Belden 88770 002 Key Features
- 3 x 18 AWG (19x30) TC - Tinned Copper conductors for multi-conductor signal and control wiring.
- FEP - Fluorinated Ethylene Propylene insulation with color code: Black, White, Red.
- Overall Beldfoil® tape shield with 100% coverage and a 20 AWG (19x32) TC drainwire to support shield termination.
- FEP - Fluorinated Ethylene Propylene outer jacket in red.
- UL voltage rating: 300 V (CMP) and UL temperature: 150°C.
- Environmental suitability includes indoor, outdoor, sunlight resistance, oil resistance, and burial.
- Flammability / reaction to fire: NFPA 262, UL 910 (Plenum), IEC 60332-1-2.
Belden 88770 002 Applications
- Use it in extreme high/low temperature environments where stable operation across wide temperature swings is needed.
- Choose it for chemical resistant installations where exposure to chemicals is a concern.
- Install it in outdoor and burial applications for runs that must be placed outside or underground.
- Support low voltage analog signals (4-20ma, 0-10v, ...) for common instrumentation and signal transmission needs.
- Wire low voltage control (24v, …) circuits where control signaling is required.
- Use it in line level audio installations for audio signal interconnects.
- Deploy it in voice communications systems where clear signal transmission is required.
- Use it for panel wiring to support internal wiring and interconnections within control panels.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 18 AWG |
| Stranding | 19x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation thickness (nom.) | 0.007 in (0.18 mm) |
| Insulation diameter (nom.) | 0.057 in (1.4 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drain Wire | 20 AWG (19x32) TC |
| Jacket thickness (nom.) | 0.014 in (0.36 mm) |
| Overall diameter (Nom.) | 0.155 in (3.94 mm) |
| Shield DCR (nom.) | 8 Ohm/1000ft (26 Ohm/km) |
| Nom. conductor DCR | 7.06 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 54 pF/ft (180 pF/m) |
| Capacitance, Cond-to-other (conds + Shield) (nom.) | 96 pF/ft (310 pF/m) |
| Max. current | 17 Amps per Conductor at 30ºC |
| Operating temperature | -20°C to +150°C |
| Bend radius (stationary min.) | 1.6 in (41 mm) |
| Bend radius (installation min.) | 1.6 in (41 mm) |
| Max Pull Tension | 89.1 lbs (40.4 kg) |
| Bulk cable weight | 28 lbs/1000ft |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Non-Plenum number | 8770 |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 88770 002100, 88770 002250, 88770 002500, 88770 0021000, UPC 612825217411 |
| Priced Per | FT |