Belden 88778 002, Multi Conductor Cable 6C 22 AWG Shielded FEP

Description
Belden 88778 002 is an audio, control & instrument cable with 6 twisted pairs of 22 AWG stranded (7x30) TC - Tinned Copper conductors and an FEP - Fluorinated Ethylene Propylene outer jacket in Red. Each pair is individually shielded with Beldfoil® (100% coverage) and includes a 22 AWG (19x34) TC drain wire. It is rated UL Voltage Rating: 300 V (CMG) and UL temperature: 150°C, with an operating temperature of -70°C to +200°C. Environmental suitability includes Indoor, Sunlight Resistance, UV Resistance, and Oil Resistance.
Belden 88778 002 Key Features
- 6 twisted pairs of 22 AWG stranded (7x30) TC - Tinned Copper conductors for audio, control & instrument signal wiring.
- FEP - Fluorinated Ethylene Propylene insulation and an FEP - Fluorinated Ethylene Propylene outer jacket in Red.
- Individually shielded pairs using Beldfoil® with 100% coverage for noise rejection.
- 22 AWG (19x34) TC drain wire with shield construction listed as Indivl/foil side & drain out.
- UL Voltage Rating: 300 V (CMG) and UL temperature: 150°C.
- Operating temperature: -70°C to +200°C.
- Environmental suitability: Indoor, Sunlight Resistance, UV Resistance, Oil Resistance.
Belden 88778 002 Applications
- Use it in extreme high/low temperature environments where stable operation across -70°C to +200°C is required.
- Choose it where Chemical Resistant performance is needed and exposure to chemicals is a concern.
- Install it in outdoor and burial applications, including runs with Sunlight Resistance and UV Resistance requirements.
- It is commonly used for low voltage analog signals (4-20ma, 0-10v, ...).
- It is also used for low voltage digital control (24v, …).
- Run it for line level audio where individually shielded pairs help with noise rejection.
- Use it for voice communications wiring.
- Apply it in panel wiring for organized control and instrumentation interconnects.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 6 |
| Element type | pair(s) |
| Insulation thickness (nom.) | 0.010 in (0.25 mm) |
| Insulation diameter (nom.) | 0.049 in (1.2 mm) |
| Color Code | Black & Red, Black & White, Black & Green, Black & Blue, Black & Yellow, Black & Brown |
| Inner shield (each pair) | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket thickness (nom.) | 0.020 in (0.51 mm) |
| Overall cable diameter (nom.) | 0.321 in (8.15 mm) |
| Bulk cable weight | 70 lbs/1000ft |
| Non-Plenum number | 8778 |
| Conductor DCR (nom.) | 18.2 Ohm/1000ft |
| Conductor DCR (max.) | 160 Ohm/km |
| Inner shield DCR (nom.) | 11.54 Ohm/1000ft (37.86 Ohm/km) |
| Capacitance, Cond-to-Cond (nom.) | 31 pF/ft (100 pF/m) |
| Capacitance, Cond-to-other (nom.) | 67 pF/ft (220 pF/m) |
| Characteristic impedence (nom.) | 50 Ohm |
| Inductance (nom.) | 0.18 µH/ft (0.59 µH/m) |
| Velocity of prop. (nom.) | 69% |
| Max. current | 1.96 Amps per Conductor at 25ºC |
| Bend radius (stationary min.) | 3.1 in (79 mm) |
| Bend radius (installation min.) | 3.1 in (79 mm) |
| Max Pull Tension | 128 lbs (58.1 kg) |
| Flammability / reaction to fire | NFPA 262 (UL910), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 88778 002100, 88778 002250, 88778 002500, 88778 0021000, UPC 612825217473 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.