Belden 89182 010, Multi Pair Cable 1 Pair 22 AWG FEP Jacket, Black Jacket

Description
Belden 89182 010 is a 150 Ohm twinax 1 pair 22 AWG cable with a black FEP jacket for plenum installations. It uses 22 AWG stranded (19x34) TC - Tinned Copper conductors with FEP - Fluorinated Ethylene Propylene (Foam) insulation and an overall Duofoil® shield with 100% coverage. Key electrical characteristics include 14.0 Ohm/1000ft nominal conductor DCR (Pair(s)), 78% nominal velocity of propagation (Pair(s)), and a UL voltage rating of 300 V RMS (CL2P, CMP). It is listed with CMP and NFPA 262 and includes published attenuation values from 1 MHz to 400 MHz.
Belden 89182 010 Key Features
- 150 Ohm twinaxial coax construction with 1 pair for controlled-impedance signal transmission.
- 22 AWG stranded (19x34) TC - Tinned Copper conductors with a 0.030 in nominal conductor diameter.
- FEP - Fluorinated Ethylene Propylene (Foam) insulation with a 0.130 in (3.30 mm) nominal insulation diameter and black & yellow color code.
- Overall tape shield using Tri-Laminate (Alum+Poly+Alum) Duofoil® with 100% coverage.
- FEP - Fluorinated Ethylene Propylene jacket in black with a 0.307 in (7.80 mm) nominal overall cable diameter.
- Plenum-rated compliance details include NFPA 262 and NEC / UL compliance: Article 725, Article 800, CL2P, CMP.
Belden 89182 010 Applications
- Supports harsh environment installations where durable signal cabling is required.
- Commonly specified in IIoT deployments to connect and communicate between devices and systems.
- Fits factory or process automation environments where consistent signal performance is needed.
- Works well for video, audio, and data communication links where controlled-impedance twinax cabling is appropriate.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax Type | Twinaxial |
| Coax construction | Coaxial |
| Non-Plenum number | 9182 |
| Nom. outer shield DCR (Pair(s)) | 6.3 Ohm/1000ft (21 Ohm/km) |
| Nom. capacitance cond-to-shield (pairs) | 16.5 pF/ft (54.1 pF/m) |
| Attenuation (nominal) 1 MHz | 0.40 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.10 dB/100ft |
| Attenuation (nominal) 50 MHz | 2.75 dB/100ft |
| Attenuation (nominal) 100 MHz | 4.30 dB/100ft |
| Attenuation (nominal) 200 MHz | 6.20 dB/100ft |
| Attenuation (nominal) 400 MHz | 8.80 dB/100ft |
| Operating temperature | -70°C to +200°C |
| UL temperature | 200°C |
| Bend radius (stationary min.) | 6.25 in (159 mm) |
| Bend radius (installation min.) | 2.5 in (64 mm) |
| Max Pull Tension | 28 lbs (13 kg) |
| Bulk cable weight | 49 lbs/1000ft |
| Environmental suitability | Indoor - Plenum, Indoor, Outdoor, Aerial - When supported by messenger Wire, Burial |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 89182 010100, 89182 010250, 89182 010500, 89182 0101000 |
| Priced Per | FT |