Belden 89841 002, Multi Conductor P.O.S. Cable 1 Pair 24 AWG SH FEP Red

Description
Belden 89841 002 is a 1 pair 24 AWG RS-485 and P.O.S. multi-conductor cable with 24 AWG (7x32) TC - Tinned Copper conductors and FEP - Fluorinated Ethylene Propylene (Foam) insulation. It uses an overall shield of Beldfoil® plus a Tinned Copper braid(90%) shield and includes a 24 AWG (7x32) TC drainwire. The cable has a plenum-rated FEP - Fluorinated Ethylene Propylene outer jacket in Red and is listed CMP with a UL Voltage Rating of 300 V (CMP). Electrical characteristics include 120 Ohm nominal characteristic impedence and 12 pF/ft (39 pF/m) nominal capacitance Cond-to-Cond.
Belden 89841 002 Key Features
- 1 pair construction with 24 AWG conductors for RS-485 and P.O.S. multi-conductor cable builds.
- 24 AWG (7x32) TC - Tinned Copper conductors with a 24 AWG (7x32) TC drainwire.
- FEP - Fluorinated Ethylene Propylene (Foam) insulation with color code: White/Blue Stripe & Blue/White Stripe.
- Overall shield: Beldfoil® + Tinned Copper Braid(90%) Shield, including Tape Shield: Bi-Laminate (Alum+Poly), 100% and Braid Shield: Tinned Copper (TC), 90%.
- FEP - Fluorinated Ethylene Propylene jacket in Red with CMP listing and UL Voltage Rating: 300 V (CMP).
- Operating temperature: -70°C to +200°C; UL temperature: 200°C.
Belden 89841 002 Applications
- Supports RS-485 and POS connections where consistent serial communication is required.
- Fits computer communications links that rely on stable data transmission.
- Handles Low Voltage Analog Signals (4-20ma, 0-10v, ...) in control and monitoring circuits.
- Enables Low Voltage Digital Control (24v, …) for device control and automation signaling.
- Suitable for Line Level Audio signal runs where low-level audio needs to be carried between equipment.
- Commonly used for Panel Wiring to route signals within control panels and enclosures.
- Used in serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Pairs | 1 |
| Conductor size | 24 AWG |
| Stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Insulation thickness (nom.) | 0.025 in (0.64 mm) |
| Insulation diameter (nom.) | 0.074 in (1.9 mm) |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.204 in (5.18 mm) |
| Nom. conductor DCR | 24 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 12 pF/ft (39 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 22 pF/ft (72 pF/m) |
| Nom. characteristic impedence | 120 Ohm |
| Nom. velocity of prop. | 76% |
| Max. current | 4 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 3.1 Ohm/1000ft (10 Ohm/km) |
| Nom. insertion loss (attenuation) | 0.6 dB/100ft at 1 MHz |
| Bend radius (stationary min.) | 2.25 in (57.2 mm) |
| Bend radius (installation min.) | 2.25 in (57.2 mm) |
| Max Pull Tension | 45.7 lbs (20.7 kg) |
| Bulk cable weight | 27 lbs/1000ft |
| Environmental suitability | Indoor, Oil Resistance |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 9841, 9841ZH |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 89841 002100, 89841 002250, 89841 002500, 89841 0021000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.