Belden 9116P 010, Coaxial Cable RG6 18 Solid CCS Shielded FFPE FLRT Jacket, Black Jacket

Description
Belden 9116P 010 is a Series 6 (RG Type 6) broadband coaxial cable designed for CATV, RF drop cable, and Over-The-Air (OTA) antenna runs in indoor plenum spaces. It features an 18 AWG solid BCCS - Bare Copper Covered Steel conductor with FEP - Fluorinated Ethylene Propylene (Foam) insulation and a foil + 60% aluminum braid shield. This cable is CMP rated, meets NFPA 262, and provides 75 Ohm performance across 5 - 1000 MHz. It is finished with a black PVC - Polyvinyl Chloride jacket.
Belden 9116P 010 Key Features
- Series 6 (RG Type 6) broadband coaxial construction for RG 6 applications.
- 18 AWG solid BCCS - Bare Copper Covered Steel conductor.
- FEP - Fluorinated Ethylene Propylene (Foam) insulation with white color code.
- Shielding includes Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% foil, plus aluminum 60% braid.
- CMP rated and meets NFPA 262 for indoor plenum installations.
- Black PVC - Polyvinyl Chloride jacket with nominal overall diameter of 0.235 in (5.97 mm).
- Nom. characteristic impedance: 75 Ohm.
- Frequency range: 5 - 1000 MHz with min. structural return loss: 20 dB.
Belden 9116P 010 Applications
- Use in broadband installations requiring a Series 6 (RG Type 6) coaxial cable.
- Support Cable Television (CATV) signal distribution in indoor plenum spaces.
- Run RF drop cable connections for RF services within indoor plenum environments.
- Route coaxial runs for Over-The-Air (OTA) antennas through indoor plenum areas.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Broadband coax series | Broadband Coax, Series 6 |
| RG type | 6 |
| Coax Type | RG 6 |
| Conductor diameter (nom.) | 0.040 in |
| Insulation diameter (nom.) | 0.170 in (4.32 mm) |
| Shield Type | Both, braid over foil |
| Flooded | No not flooded over braid |
| Bulk cable weight | 25 lbs/1000ft |
| Nom. velocity of prop. | 83% |
| Nom. capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 28 Ohm/1000ft |
| Nom. outer shield DCR | 9 Ohm/1000ft (30 Ohm/km) |
| UL Voltage Rating | 300 V (CMP) |
| Attenuation @ 1 MHz | 0.3 dB/100ft |
| Attenuation @ 10 MHz | 0.7 dB/100ft |
| Attenuation @ 50 MHz | 1.6 dB/100ft |
| Attenuation @ 100 MHz | 2.1 dB/100ft |
| Attenuation @ 200 MHz | 2.9 dB/100ft |
| Attenuation @ 400 MHz | 4.3 dB/100ft |
| Attenuation @ 700 MHz | 6.1 dB/100ft |
| Attenuation (750 MHz) | 6.4 dB/100ft |
| Attenuation @ 900 MHz | 7.1 dB/100ft |
| Attenuation @ 1000 MHz | 7.6 dB/100ft |
| Operating temperature | -20°C to +75°C |
| Bend radius (installation min.) | 3 in (76 mm) |
| Max Pull Tension | 150 lbs (68 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| Fire rating | Plenum |
| Flammability / reaction to fire | NFPA 262 |
| Non-Plenum number | 9116, 9116R |
| CEC / C(UL) compliance | CMP |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 9116P 010100, 9116P 010250, 9116P 010500, 9116P 0101000, UPC t 612825224464 |