Belden 9251 010, RG 8 U Coax Cable 13 AWG Stranded PVC Jacket, Black Jacket

Description
Belden 9251 010 is an RG-8/U type coax cable with a 13 AWG stranded (7x21) bare copper (BC) conductor, PE - Polyethylene insulation, and a black PVC - Polyvinyl Chloride (Non-Contaminating) jacket. It features a bare copper (BC) braid shield with 95% coverage and a nominal characteristic impedance of 52 Ohm. Belden 9251 010 is listed as CMX and VW-1, with a UL temperature rating of 60°C and an operating temperature range of -40°C to +80°C.
Belden 9251 010 Key Features
- RG-8/U type coax construction with number of coax: 1 and number of conductors: 1.
- 13 AWG stranded (7x21) bare copper (BC) conductor with conductor nominal diameter: 0.085 in.
- PE - Polyethylene insulation with insulation nominal diameter: 0.285 in.
- Bare copper (BC) braid outer shield with shield coverage: 95% to help reduce interference.
- Black PVC - Polyvinyl Chloride (Non-Contaminating) jacket with jacket nominal diameter: 0.405 in.
- NEC/(UL) compliance: CMX and CEC/C(UL) compliance: CMX, plus UL flammability: VW-1.
Belden 9251 010 Applications
- Used for 50 Ohm transmission applications where a coaxial cable format is required.
- Suitable for computer applications where consistent electrical performance is needed.
- Intended for indoor installations in an environmental space: Indoor (Not Riser or Plenum).
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| RG type | 8 |
| Insulation nominal wall thickness | 0.285 in |
| Outer shield type | Braid |
| Nominal characteristic impedance | 52 Ohm |
| Nominal conductor DCR | 1.9 Ohm/1000ft |
| Nominal outer shield DCR | 1.2 Ohm/1000ft |
| Non-UL voltage rating | 3700 V RMS |
| UL Voltage Rating | 150 V RMS; 30 V RMS (UL AWM Style 1354) |
| Bulk cable weight | 105 lbs/1000ft |
| Nom. capacitance (Conductor to Shield) | 28.5 pF/ft |
| Nominal inductance | 0.079 µH/ft |
| Nominal delay | 1.54 ns/ft |
| Nominal velocity of propagation (VP) [%] | 66% |
| High frequency (nominal/typical) – insertion loss | 1 MHz: 0.2 dB/100ft; 10 MHz: 0.6 dB/100ft; 50 MHz: 1.3 dB/100ft; 100 MHz: 1.9 dB/100ft; 200 MHz: 2.8 dB/100ft; 400 MHz: 4.2 dB/100ft; 700 MHz: 5.9 dB/100ft; 900 MHz: 6.9 dB/100ft; 1000 MHz: 7.4 dB/100ft; 4000 MHz: 23.2 dB/100ft |
| UL Temperature Rating | 60°C |
| Operating Temperature Range | -40°C To +80°C |
| Maximum recommended pulling tension | 190 lbs |
| Minimum minor axis bend radius | 4 in |
| Plenum (Y/N) | No |
| Environmental space | Indoor (Not Riser or Plenum) |
| Suitability - indoor | Yes |
| Suitability - Outdoor | Yes |
| Suitability - aerial | Yes |
| UL AWM style compliance | AWM 1354 (30 V 60°C) |
| EU CE mark | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS) | Yes |
| Footnote | C - CRATE REEL PUT-UP. |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 9251 010100, 9251 010250, 9251 010500, 9251 0101000, UPC 612825225775 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.