Belden 9271 006, Twinax TW PR FS PVC Light Blue

SKU:Belden 9271 006
● In stock
Description
Belden 9271 006 is a 124 Ohm twinax cable built for impedance-controlled, high-frequency signal transmission. It features 25 AWG Stranded (7x33) TC - Tinned Copper conductors with PE - Polyethylene insulation, plus a Beldfoil® tape shield with 100% coverage and a 22 AWG TC - Tinned Copper drain wire. A PVC - Polyvinyl Chloride jacket in Blue provides protection for general-purpose installations. The cable is rated UL AWM Style 2092 at 300 V RMS and 60°C.
Belden 9271 006 Key Features
- 124 Ohm nominal characteristic impedance supports impedance-controlled signal applications.
- Twinax construction with 2 conductors (1 pair) supports balanced signal transmission.
- 25 AWG Stranded (7x33) TC - Tinned Copper conductors support flexible terminations.
- Beldfoil® tape shield (Bi-Laminate (Alum+Poly)) with 100% coverage and a 22 AWG TC - Tinned Copper drain wire (7x30) supports grounding.
- PVC - Polyvinyl Chloride jacket in Blue provides general-purpose cable protection.
- UL AWM Style 2092 rating: 300 V RMS and 60°C.
Belden 9271 006 Applications
- Use in instrumentation, data, and other impedance-controlled applications where consistent signal performance is required.
- Support high-frequency signal transmission with nominal insertion loss values specified from 1 MHz to 400 MHz.
- Fit general-purpose installations where a PVC jacket is used for cable protection.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Cable type | Twinax |
| Number of Conductors | 2 |
| Number of pairs | 1 |
| Nominal Conductor Diameter | 0.021 in |
| Insulation Material | PE - Polyethylene |
| Insulation wall thickness | 0.031 in |
| Conductor colors | Blue & Clear |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield trade name | Beldfoil® |
| Shield Coverage | 100% |
| Jacket diameter | 0.24 in |
| Jacket wall thickness | 0.035 in |
| Bulk cable weight | 25 lbs/1000ft |
| Nominal conductor DCR | 31.8 Ohm/1000ft |
| Nominal outer shield DCR | 12 Ohm/1000ft |
| Capacitance (Conductor-to-Conductor) | 12.2 pF/ft |
| Capacitance, conductor to other conductor to shield | 22 pF/ft |
| Nominal inductance | 0.188 µH/ft |
| Max. delay skew | 66 ns/100m |
| Nominal delay | 1.54 ns/ft |
| Nominal velocity of propagation (VP) [%] | 66% |
| Insertion loss @ 1 MHz (nominal) | 0.6 dB/100ft |
| Insertion loss @ 10 MHz (nominal) | 1.7 dB/100ft |
| Insertion loss @ 50 MHz (nominal) | 3.6 dB/100ft |
| Insertion loss @ 100 MHz (nominal) | 5 dB/100ft |
| Insertion loss @ 200 MHz (nominal) | 6.9 dB/100ft |
| Insertion loss @ 400 MHz (nominal) | 9.6 dB/100ft |
| Operating Temperature Range | -20°C to +60°C |
| Maximum recommended pulling tension | 17 lbs |
| Minimum minor axis bend radius | 2.5 in |
| Plenum (Y/N) | No |
| NEC / UL compliance | CM |
| CEC / C(UL) compliance | CM |
| UL AWM style compliance | AWM 2092 (300 V 60°C) |
| CPR Euroclass | Eca |
| EU directive compliance | Yes |
| EU CE mark | Yes |
| MII Order #39 (China RoHS) | Yes |
| UL flammability | UL1685 UL Loading |
| IEC flammability | IEC 60332-1-2 |
| Footnote | C - CRATE REEL PUT-UP. |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 9271 006100, 9271 006250, 9271 006500, 9271 0061000, UPC 612825226208 |
| Priced Per | FT |