Belden 9272 006, Twinaxial Cable 78 OHM Light Blue

SKU:Belden 9272 006
● In stock
Description
Belden 9272 006 is a 78 Ohm twinaxial cable for RF applications, built with 20 AWG stranded (7x28) 0.038 in TC - Tinned Copper conductors and PE - Polyethylene insulation. It features a Tinned Copper (TC) braid shield with 93% coverage and a PVC - Polyvinyl Chloride jacket in Blue. Electrical characteristics include 19.7 pF/ft capacitance, 0.020 μH/ft inductance, and UL Voltage Rating: 300 V RMS. Insertion loss is specified from 1 MHz through 400 MHz.
Belden 9272 006 Key Features
- 78 Ohm nominal characteristic impedance for twinaxial RF signal transmission.
- 2 conductors: 20 AWG stranded (7x28) TC - Tinned Copper with 0.038 in nominal conductor diameter.
- PE - Polyethylene insulation with 0.0755 in insulation nominal diameter.
- Tinned Copper (TC) braid outer shield with 93% shield coverage.
- PVC - Polyvinyl Chloride jacket in Blue with 0.244 in jacket nominal diameter.
- UL Voltage Rating: 300 V RMS.
- UL Temperature Rating: 60°C (UL AWM Style 2092) and Operating Temperature Range: -30°C To +75°C.
- Insertion loss values provided at 1 MHz, 10 MHz, 50 MHz, 100 MHz, 200 MHz, and 400 MHz.
Belden 9272 006 Applications
- Use in RF applications where consistent impedance and shielding performance matter.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax construction | Twinaxial |
| Coax Type | Twinaxial |
| Bulk cable weight | 38 lbs/1000ft |
| Nominal conductor DCR | 9.5 Ohm/1000ft |
| Nominal outer shield DCR | 3.4 Ohm/1000ft |
| Nom. capacitance conductor to conductor | 19.7 pF/ft |
| Nom. capacitance (Conductor to Shield) | 19.7 pF/ft |
| Nominal inductance | 0.020 µH/ft |
| Nominal delay | 1.54 ns/ft |
| Max. delay skew | 66 ns/100m |
| Nominal velocity of propagation (VP) [%] | 66% |
| 1 MHz nominal insertion loss | 0.6 dB/100ft |
| 10 MHz nominal insertion loss | 2.1 dB/100ft |
| 50 MHz nominal insertion loss | 5.0 dB/100ft |
| 100 MHz nominal insertion loss | 7.5 dB/100ft |
| 200 MHz nominal insertion loss | 11 dB/100ft |
| 400 MHz nominal insertion loss | 16 dB/100ft |
| Maximum recommended pulling tension | 55 lbs |
| Minimum minor axis bend radius | 2.5 in |
| NEC / UL compliance | CM |
| CEC / C(UL) compliance | CM |
| UL AWM style compliance | AWM 2092 (300 V 60°C) |
| CPR Euroclass | Eca |
| UL flammability | UL 1685 UL Loading |
| IEC flammability | IEC 60332-1-2 |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | No |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU directive compliance | Yes |
| EU CE mark | Yes |
| MII Order #39 (China RoHS) | Yes |
| Suitability - indoor | Yes |
| Suitability - Outdoor | Yes - Black only |
| Suitability - aerial | Yes - Black only, when supported by messenger Wire |
| Suitability - burial | No |
| Suitability - hazardous locations | No |
| Plenum (Y/N) | No |
| Plenum number | 89272 |
| Footnote | C - CRATE REEL PUT-UP. |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 9272 006100, 9272 006250, 9272 006500, 9272 0061000, UPC 612825226253 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.