Belden 9329 060, Power Limited Tray Cable 3PR 22 AWG 300V PVC, Chrome Jacket

SKU:Belden 9329 060
● In stock
× 100 ft = Total: 100 ft
Description
Belden 9329 060 is an instrumentation PLTC tray cable for signal transmission in control and monitoring circuits. It features 3 pair 22 AWG (7x30) TC - Tinned Copper conductors with PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride outer jacket in Chrome. Each pair includes an individual Beldfoil® shield to support noise rejection. The cable is rated 300 V (PLTC, CMG) and is listed for Indoor/Outdoor use with Sunlight Resistance.
Belden 9329 060 Key Features
- 3 pair construction with 22 AWG (7x30) TC - Tinned Copper stranded conductors.
- Each pair has an individual Beldfoil® shield with 100% coverage using Bi-Laminate (Alum+Poly) tape.
- 300 V (PLTC, CMG) UL voltage rating for instrumentation and control wiring.
- PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride outer jacket in Chrome.
- Indoor/Outdoor suitability with Sunlight Resistance.
- Includes a ripcord for easier installation and handling.
Belden 9329 060 Applications
- Used for instrumentation signal transmission in control and monitoring circuits.
- Often connects sensors, valves, and positioners in instrumentation systems.
- Supports analog signal wiring such as 4-20mA and 0-10V in control and monitoring setups.
- Fits Indoor/Outdoor installations where Sunlight Resistance is required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Element type | Pair(s) |
| Number of elements | 3 |
| Conductor Type | Stranded conductor |
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Color Code | ICEA Chart E2 |
| Shield | Yes - this has a shield |
| Shield Type | Tape |
| Drainwire type | 22 AWG (7x30) TC |
| Shield notes | each pair |
| Separator | Cotton Serve |
| Armor | No |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Overall cable diameter (nom.) | 0.341 in (8.66 mm) |
| Bulk cable weight | 53 lbs/1000ft |
| Nom. conductor DCR | 18.2 Ohm/1000ft |
| Nom. inner shield DCR | 13.37 Ohm/1000ft (43.86 Ohm/km) |
| Nom. capacitance cond-to-cond | 26 pF/ft (85 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 45 pF/ft (150 pF/m) |
| Nom. inductance | 0.21 µH/ft (0.69 µH/m) |
| Max. current | 3.4 Amps per Conductor at 25ºC |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 3.4 in (86 mm) |
| Bend radius (installation min.) | 3.4 in (86 mm) |
| Max Pull Tension | 63 lbs (29 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9329 060100; 9329 060250; 9329 060500 UPC 612825230311; 9329 0601000 UPC 612825230304; 9329 0605000 UPC 612825230328 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.