Belden 9329 060, Power Limited Tray Cable 3PR 22 AWG 300V PVC, Chrome Jacket

Description
Belden 9329 060 is an instrumentation PLTC tray cable for signal transmission in control and monitoring circuits. It features 3 pair 22 AWG (7x30) TC - Tinned Copper conductors with PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride outer jacket in Chrome. Each pair includes an individual Beldfoil® shield to support noise rejection. The cable is rated 300 V (PLTC, CMG) and is listed for Indoor/Outdoor use with Sunlight Resistance.
Belden 9329 060 Key Features
- 3 pair construction with 22 AWG (7x30) TC - Tinned Copper stranded conductors.
- Each pair has an individual Beldfoil® shield with 100% coverage using Bi-Laminate (Alum+Poly) tape.
- 300 V (PLTC, CMG) UL voltage rating for instrumentation and control wiring.
- PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride outer jacket in Chrome.
- Indoor/Outdoor suitability with Sunlight Resistance.
- Includes a ripcord for easier installation and handling.
Belden 9329 060 Applications
- Used for instrumentation signal transmission in control and monitoring circuits.
- Often connects sensors, valves, and positioners in instrumentation systems.
- Supports analog signal wiring such as 4-20mA and 0-10V in control and monitoring setups.
- Fits Indoor/Outdoor installations where Sunlight Resistance is required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Element type | Pair(s) |
| Number of elements | 3 |
| Conductor Type | Stranded conductor |
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Color Code | ICEA Chart E2 |
| Shield | Yes - this has a shield |
| Shield Type | Tape |
| Drainwire type | 22 AWG (7x30) TC |
| Shield notes | each pair |
| Separator | Cotton Serve |
| Armor | No |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Overall cable diameter (nom.) | 0.341 in (8.66 mm) |
| Bulk cable weight | 53 lbs/1000ft |
| Nom. conductor DCR | 18.2 Ohm/1000ft |
| Nom. inner shield DCR | 13.37 Ohm/1000ft (43.86 Ohm/km) |
| Nom. capacitance cond-to-cond | 26 pF/ft (85 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 45 pF/ft (150 pF/m) |
| Nom. inductance | 0.21 µH/ft (0.69 µH/m) |
| Max. current | 3.4 Amps per Conductor at 25ºC |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 3.4 in (86 mm) |
| Bend radius (installation min.) | 3.4 in (86 mm) |
| Max Pull Tension | 63 lbs (29 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9329 060100; 9329 060250; 9329 060500 UPC 612825230311; 9329 0601000 UPC 612825230304; 9329 0605000 UPC 612825230328 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.