Belden 9330 060, Power Limited Tray Cable 8C 22 AWG 300V PVC, Chrome Jacket

SKU:Belden 9330 060
● In stock
Description
Belden 9330 060 is an instrumentation cable designed for reliable signal transmission in control and monitoring circuits. It features 4 pair 22 AWG (7x30) TC - Tinned Copper conductors with PVC - Polyvinyl Chloride insulation and an ICEA Chart E2 color code for identification. Each pair is individually Beldfoil® shielded with 100% coverage and includes a 22 AWG (7x30) TC drainwire to help reduce noise. The PVC - Polyvinyl Chloride outer jacket in Chrome supports indoor/outdoor use and sunlight resistance, with a UL voltage rating of 300 V (PLTC, CMG).
Belden 9330 060 Key Features
- 4 pair 22 AWG (7x30) TC - Tinned Copper conductors for instrumentation signal wiring.
- PVC - Polyvinyl Chloride insulation with ICEA Chart E2 color code for consistent identification.
- Each pair is individually Beldfoil® shielded (Tape, Bi-Laminate (Alum+Poly)) with 100% coverage and a 22 AWG (7x30) TC drainwire to help reduce noise.
- PVC - Polyvinyl Chloride outer jacket in Chrome suitable for indoor/outdoor use and sunlight resistance.
- UL voltage rating: 300 V (PLTC, CMG).
Belden 9330 060 Applications
- Use in instrumentation circuits that require reliable signal transmission for control and monitoring.
- Support sensors and positioners where shielded pairs help reduce noise in signal wiring.
- Connect valves and related control wiring in systems that use 4-20mA or 0-10V signals.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 4 |
| Element type | pair(s) |
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Shield | Yes - this has a shield |
| Shield notes | each pair |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Separator | Cotton Serve |
| Ripcord | Yes |
| Overall cable diameter (nom.) | 0.372 in (9.45 mm) |
| Armor | No |
| Bulk cable weight | 65 lbs/1000ft |
| Nom. conductor DCR | 18.2 Ohm/1000ft |
| Nom. inner shield DCR | 13.37 Ohm/1000ft (43.86 Ohm/km) |
| Nom. capacitance cond-to-cond | 26 pF/ft (85 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 45 pF/ft (150 pF/m) |
| Nom. inductance | 0.21 µH/ft (0.69 µH/m) |
| Max. current | 3 Amps per Conductor at 25ºC |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Stationary min. bend radius | 3.7 in (94 mm) |
| Installation min. bend radius | 3.7 in (94 mm) |
| Max Pull Tension | 82 lbs (37 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9330 060100; 9330 060250; 9330 060500 UPC 612825230489; 9330 0601000 UPC 612825230472; 9330 0605000 UPC 612825230496 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.