Belden 9332 060, Power Limited Tray Cable 9PR 22 AWG 300V PVC, Chrome Jacket

Description
Belden 9332 060 is an instrumentation Power Limited Tray Cable (PLTC) designed for signal transmission in control and monitoring systems. It features 9 pair 22 AWG (7x30) TC - Tinned Copper conductors with PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride outer jacket in Chrome. Each pair includes an Individual Foil Shield with 100% coverage and a 22 AWG (7x30) TC drainwire. UL Voltage Rating is 300 V (PLTC) with UL temperature 105°C and an operating range of -30°C To +105°C.
Belden 9332 060 Key Features
- 9 pair construction with 22 AWG (7x30) stranded TC - Tinned Copper conductors.
- PVC - Polyvinyl Chloride insulation and PVC - Polyvinyl Chloride outer jacket.
- Individual Foil Shield over each pair with 100% coverage and a 22 AWG (7x30) TC drainwire.
- UL Voltage Rating: 300 V (PLTC).
- UL temperature: 105°C; Operating: -30°C To +105°C.
- Ripcord: Yes.
- Jacket color: Chrome.
Belden 9332 060 Applications
- Supports instrumentation signal transmission in control and monitoring systems.
- Works with sensors, valves, and positioners where consistent signal delivery is required.
- Fits 4-20mA and 0-10V signal applications in control and monitoring setups.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 9 |
| Element type | pair(s) |
| Conductor Type | Stranded Conductor |
| Nom. thickness (insulation) | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.062 in (1.6 mm) |
| Color Code | Black, Red and Numbered |
| Nom. thickness (outer jacket) | 0.053 in (1.3 mm) |
| Nom. diameter | 0.53 in |
| Armor | No |
| Thermocouple | No |
| Inner shield element | Each Pair |
| Inner shield type | Tape |
| Inner shield material | Bi-Laminate (Alum+Poly) |
| Nom. conductor DCR | 18.2 Ohm/1000ft |
| Nom. inner shield DCR | 2.1 Ohm/1000ft (6.9 Ohm/km) |
| Nom. capacitance cond-to-cond | 26 pF/ft (85 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 45 pF/ft (150 pF/m) |
| Nom. inductance | 0.21 µH/ft (0.69 µH/m) |
| Max. current | 2.4 Amps per Conductor at 25ºC |
| Max Pull Tension | 245.7 lbs (111.4 kg) |
| Bulk cable weight | 134 lbs/1000ft |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL 1685 FT4 loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 725, Article 727, Article 800 |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9332 060100; 9332 060250; 9332 060500 UPC 612825231134; 9332 0601000 UPC 612825231127 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.