Belden 9341 010, Tray Cable 2C 18 AWG Shield 600V PVC Nyl

SKU:Belden 9341 010
● In stock
Description
Belden 9341 010 is an instrumentation tray cable designed for signal transmission in industrial control and low voltage digital control environments. It is built with 1 pair 18 AWG (19x30) TC - Tinned Copper conductors, PVC/Nylon - Polyvinyl Chloride + Nylon insulation, and ICEA Chart E2 color code. The cable includes a tape shield with Bi-Laminate (Alum+Poly) material and 100% coverage, plus a black PVC - Polyvinyl Chloride outer jacket. Key ratings and compliance details include UL Voltage Rating: 600 V (TC), 150 V (NPLF) and UL temperature: 90°C Dry, 90°C Wet.
Belden 9341 010 Key Features
- 1 pair 18 AWG (19x30) TC - Tinned Copper conductors for instrumentation and control wiring.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with ICEA Chart E2 color code for consistent conductor identification.
- Tape shield with Bi-Laminate (Alum+Poly) material and 100% coverage, plus an 18 AWG (19x30) TC drainwire.
- Black PVC - Polyvinyl Chloride outer jacket with cotton serve separator and ripcord: Yes.
- UL Voltage Rating: 600 V (TC), 150 V (NPLF).
- UL temperature: 90°C Dry, 90°C Wet.
- Environmental suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial.
Belden 9341 010 Applications
- Use it in industrial control systems where reliable signal transmission is required.
- Install it in raceways, cable trays, and ducts for organized routing in control and instrumentation runs.
- Apply it in digital control and low voltage digital control (24v, …) circuits.
- Specify it for instruments (4-20ma, 0-10v, ...) where signal integrity is important.
- Deploy it in control circuits used with distributed control system (DCS) and programmable logic controller (PLC) equipment.
- Connect it to encoders and other control feedback connections.
- Use it for actuator, positioner, solenoid, and valve control wiring where consistent control signaling is needed.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Insulation nominal thickness | 0.022 in (0.56 mm) |
| Nominal insulation diameter | 0.088 in (2.2 mm) |
| Overall cable diameter (nominal) | 0.274 in (6.96 mm) |
| Jacket nominal thickness | 0.047 in (1.2 mm) |
| Jacket nominal diameter | 0.274 in (6.96 mm) |
| Bulk cable weight | 40 lbs/1000ft |
| Nom. conductor DCR | 7.06 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 43 pF/ft (140 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 74 pF/ft (240 pF/m) |
| Nom. inductance | 0.19 µH/ft (0.62 µH/m) |
| Max. current | 5 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 5.14 Ohm/1000ft (16.9 Ohm/km) |
| Operating temperature | -30°C to +90°C Dry, 75°C wet |
| Bend radius (stationary min.) | 2.7 in (69 mm) |
| Bend radius (installation min.) | 2.7 in (69 mm) |
| Max Pull Tension | 74.1 lbs (33.6 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202, FT4 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9341 010100; 9341 010250; 9341 010500 UPC 612825231936; 9341 0101000 UPC 612825231912; 9341 0105000 UPC 612825231943; 9341 01010000 UPC 612825231929 |