Belden 9363 060U, Power Limited Tray Cable 1 Triads 22 AWG 300V PVC, Chrome Jacket

SKU:Belden 9363 060U1000
● In stock
Description
Belden 9363 060U is an instrumentation PLTC cable built with 1 triad of 22 AWG (7x30) TC - Tinned Copper conductors and a PVC - Polyvinyl Chloride outer jacket in Chrome. It features PVC - Polyvinyl Chloride insulation with a Black , White , Red color code and an overall Beldfoil® shield with 100% coverage to help reduce noise. This cable is rated 300 V (PLTC, CMG) and 105°C, with environmental suitability listed for Indoor/Outdoor and Sunlight Resistance. A ripcord is included to support easier installation.
Belden 9363 060U Key Features
- 1 triad(s) construction with 22 AWG stranded conductors (7x30) in TC - Tinned Copper.
- PVC - Polyvinyl Chloride insulation with Black , White , Red color code.
- Overall Beldfoil® shield with 100% coverage; tape shield made from Bi-Laminate (Alum+Poly) with a 22 AWG (7x30) TC drainwire.
- PVC - Polyvinyl Chloride outer jacket in Chrome with ripcord.
- UL voltage rating: 300 V (PLTC, CMG); UL temperature: 105°C.
- Environmental suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance.
Belden 9363 060U Applications
- Use in instrumentation installations requiring reliable signal transmission in control and measurement circuits.
- Connect sensors in environments where an overall shield is used to help reduce noise.
- Support valve wiring in control systems that use instrumentation cabling.
- Connect positioners in control and measurement circuits.
- Run RTD circuits where instrumentation cabling is specified.
- Carry 4-20mA signals in control and measurement circuits.
- Carry 0-10V signals in control and measurement circuits.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 1 |
| Element type | Triad(s) |
| Conductor Type | Stranded Conductor |
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Nom. diameter | 0.210 in (5.33 mm) |
| Overall cable diameter (nominal) | 0.210 in (5.33 mm) |
| Armor | No |
| Bulk cable weight | 24 lbs/1000ft |
| Shield | Yes - this has a Shield |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield type (overall) | Overall aluminum mylar Foil Shield |
| Nom. conductor DCR | 18.2 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 26 pF/ft (85 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 45 pF/ft (150 pF/m) |
| Nom. inductance | 0.21 µH/ft (0.69 µH/m) |
| Max. current | 2.8 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 12.86 Ohm/1000ft (42.19 Ohm/km) |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 2.1 in (53 mm) |
| Bend radius (installation min.) | 2.1 in (53 mm) |
| Max Pull Tension | 36 lbs (16 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9363 060U1000 UPC 612825239383 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.