Belden 9365 060, Power Limited Tray Cable 1 Triads 18 AWG 300V PVC, Chrome Jacket

Description
Belden 9365 060 is an instrumentation Power Limited Tray Cable (PLTC) designed for signal transmission in industrial control and monitoring circuits. It features 1 triad 18 AWG (19x30) tinned copper conductors, PVC insulation, and an overall Beldfoil® shield. The cable is rated 300 V (PLTC, CMG) and 105°C, with a PVC outer jacket in Chrome. Environmental suitability includes Indoor/Outdoor, Sunlight Resistance, and Burial.
Belden 9365 060 Key Features
- 1 triad(s) construction with 18 AWG (19x30) TC - Tinned Copper stranded conductors.
- PVC - Polyvinyl Chloride insulation with ICEA Chart E1 color code.
- Overall shielded design using Tape with Bi-Laminate (Alum+Poly) at 100% coverage, plus a 20 AWG (19x32) TC drainwire.
- PVC - Polyvinyl Chloride outer jacket in Chrome with PP - Polypropylene Tape separator and ripcord.
- Rated 300 V (PLTC, CMG) and 105°C.
- Environmental suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial.
Belden 9365 060 Applications
- Use in instrumentation applications requiring signal transmission in industrial control and monitoring circuits.
- Connect sensors in control and monitoring circuits.
- Support valves within industrial control and monitoring circuits.
- Connect positioners in instrumentation and control systems.
- Run RTD connections in instrumentation circuits.
- Carry 4-20mA signal loops in industrial control and monitoring circuits.
- Support 0-10V signal runs in instrumentation and monitoring applications.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Elements | Triad(s) |
| No. of elements | 1 |
| Conductor Type | Stranded Conductor |
| Insulation thickness (nom.) | 0.019 in (0.48 mm) |
| Insulation diameter (nom.) | 0.082 in (2.1 mm) |
| Shield | Yes - this has a Shield |
| Armor | No |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Overall cable diameter (nominal) | 0.269 in (6.83 mm) |
| Bulk cable weight | 48 lbs/1000ft |
| Nom. conductor DCR | 7.2 Ohm/1000ft |
| Nom. outer shield DCR | 5.66 Ohm/1000ft (18.6 Ohm/km) |
| Capacitance, Cond-to-Cond (nom.) | 54 pF/ft (180 pF/m) |
| Capacitance, Cond-to-other (nom.) | 101 pF/ft (331 pF/m) |
| Characteristic impedence (nom.) | 45 Ohm |
| Inductance (nom.) | 0.17 µH/ft (0.56 µH/m) |
| Max. current | 5 Amps per Conductor at 25ºC |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Stationary min. bend radius | 2.7 in (69 mm) |
| Installation min. bend radius | 2.7 in (69 mm) |
| Max Pull Tension | 89 lbs (40 kg) |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9365 060100; 9365 060250; 9365 060500; 9365 0601000 UPC 612825239499; 9365 0602500 UPC 612825239505; 9365 0605000 UPC 612825239512 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.