Belden 9367 060, Power Limited Tray Cable 1 Triads 14 AWG 300V PVC, Chrome Jacket

SKU:Belden 9367 060
● In stock
Description
Belden 9367 060 is an instrumentation Power Limited Tray Cable (PLTC) with 1 triad of 14 AWG (42x30) TC - Tinned Copper conductors and PVC - Polyvinyl Chloride insulation. It includes a tape shield made from Bi-Laminate (Alum+Poly) with 100% coverage and a 16 AWG (19x29) TC drainwire. The PVC - Polyvinyl Chloride jacket is Chrome, includes a ripcord, and the cable is rated UL Voltage Rating: 300 V (PLTC) with UL Temperature: 105°C.
Belden 9367 060 Key Features
- 1 triad(s) construction with No. of Elements: 1 for instrumentation signal wiring.
- 14 AWG conductors with Stranding: 42x30 and Material: TC - Tinned Copper.
- PVC - Polyvinyl Chloride insulation with Color Code: Black, White, Red.
- Tape shield using Bi-Laminate (Alum+Poly) with Coverage: 100% and Drainwire Type: 16 AWG (19x29) TC.
- PVC - Polyvinyl Chloride jacket with Ripcord: Yes and Jacket Color: Chrome.
- UL Voltage Rating: 300 V (PLTC) and UL Temperature: 105°C.
Belden 9367 060 Applications
- Use in instrumentation installations where a PLTC-rated cable is specified.
- Connect sensors, valves, and positioners in control and process environments.
- Support RTD signal wiring where shielded instrumentation cable is used.
- Run 4-20mA and 0-10V signals in instrumentation and control systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.022 in (0.56 mm) |
| Insulation diameter (nom.) | 0.119 in (3.02 mm) |
| Separator | PP - Polypropylene Tape |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Jacket diameter (nom.) | 0.358 in (9.09 mm) |
| Overall cable diameter (nominal) | 0.358 in (9.09 mm) |
| Bulk cable weight | 94 lbs/1000ft |
| Nom. conductor DCR | 2.8 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 27 pF/ft (89 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 54 pF/ft (180 pF/m) |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 8 Amps per Conductor at 25°C |
| Nom. outer shield DCR | 4.18 Ohm/1000ft (13.7 Ohm/km) |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Stationary min. bend radius | 3.6 in (91 mm) |
| Installation min. bend radius | 3.6 in (91 mm) |
| Max Pull Tension | 200 lbs (91 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL 1685 UL Loading, T-29-520, IEEE 1202, FT4 |
| NEC / UL compliance | Article 725, Article 727, CL3R, ITC, PLTC |
| AWM compliance | AWM 2464 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9367 060100; 9367 060250; 9367 060500 UPC 612825239574; 9367 0601000 UPC 612825239550; 9367 0602500 UPC 612825239567; 9367 0605000 UPC 612825239581 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.