Belden 9390 060, Power Limited Tray Cable 9PR 18 AWG 300V PVC, Chrome Jacket

SKU:Belden 9390 060
● In stock
Description
Belden 9390 060 is an instrumentation Power Limited Tray Cable (PLTC) designed for signal transmission in industrial control and monitoring systems. It features 9 pair 18 AWG (19x30) TC - Tinned Copper stranded conductors with PVC - Polyvinyl Chloride insulation and a tape shield on each pair using Bi-Laminate (Alum+Poly) with 100% coverage. The cable is rated 300 V (PLTC) and 105°C, with an operating range of -30°C to +105°C. It includes a PVC - Polyvinyl Chloride outer jacket with a ripcord in Chrome for identification.
Belden 9390 060 Key Features
- 9 pair construction with 18 AWG (19x30) TC - Tinned Copper stranded conductors.
- PVC - Polyvinyl Chloride insulation with a black, red and numbered color code.
- Individually shielded pairs with tape shielding (Bi-Laminate (Alum+Poly)) and 100% coverage.
- Includes a 20 AWG (19x32) TC drainwire for the shield system.
- PVC - Polyvinyl Chloride outer jacket with ripcord; jacket color: Chrome; armor: No.
- UL voltage rating: 300 V (PLTC) and UL temperature: 105°C.
Belden 9390 060 Applications
- Supports instrumentation signal wiring in industrial control and monitoring systems.
- Connects sensors, valves, and positioners in control circuits.
- Works for 4-20mA and 0-10V signal applications where consistent signal transmission is required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 9 |
| Element type | pair(s) |
| Conductor Type | stranded conductor |
| Insulation nominal thickness | 0.016 in (0.41 mm) |
| Insulation nominal diameter | 0.078 in (2.0 mm) |
| Outer jacket nominal thickness | 0.063 in (1.6 mm) |
| Outer diameter | 0.667 in |
| Bulk cable weight | 244 lbs/1000ft |
| Nom. conductor DCR | 7.19 Ohm/1000ft |
| Nom. inner shield DCR | 0.5 Ohm/1000ft (1.6 Ohm/km) |
| Nom. capacitance cond-to-cond | 61 pF/ft (200 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 112 pF/ft (367 pF/m) |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 7 Amps per Conductor at 25ºC |
| Max Pull Tension | 579.6 lbs (262.9 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Flammability / reaction to fire | UL 1685 FT4 loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 725, Article 727, Article 800 |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9390 060100; 9390 060250; 9390 060500 UPC 612825239864; 9390 0601000 UPC 612825239857 |