Belden 9406 T35U, Multi Conductor Cable 2C 22 AWG PVC

SKU:Belden 9406 T35U1000
● In stock
Description
Belden 9406 T35U is an audio, control & instrument cable with 22 AWG stranded (7x30) TC - Tinned Copper conductors and SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation in twisted pairs. Each pair is individually shielded with Beldfoil® (100% coverage) and includes a 22 AWG (7x30) TC drainwire to help reduce noise in sensitive signal runs. It features a PVC - Polyvinyl Chloride jacket, a UL voltage rating of 300 V, and is designed for indoor installations. Compliance includes Article 800, CMG, and AWM 2464.
Belden 9406 T35U Key Features
- 22 AWG stranded (7x30) TC - Tinned Copper conductors arranged as pair(s) with 2 elements.
- SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation in twisted pairs.
- Individually shielded pairs using Beldfoil® with 100% coverage.
- Includes a 22 AWG (7x30) TC drainwire with the inner shield.
- PVC - Polyvinyl Chloride jacket with a UL voltage rating of 300 V.
- Environmental suitability: indoor.
- NEC / UL compliance: Article 800, CMG; AWM compliance: AWM 2464.
Belden 9406 T35U Applications
- Supports low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation signal runs.
- Handles low voltage digital control (24v, …) where consistent signal handling is needed.
- Works for line level audio connections in installed systems.
- Meets computer communication wiring needs where shielded pairs are required.
- Suited for panel wiring in indoor environments.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Elements | Pair(s) |
| No. of elements | 2 |
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.051 in (1.3 mm) |
| Color Code | Black & White, Black & Yellow |
| Inner shield type | Tape |
| Inner shield material | Bi-Laminate (Alum+Poly) |
| Outer shield | No Shield |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Overall cable diameter (nom.) | 0.173 in |
| Nom. conductor DCR | 18.2 Ohm/1000ft |
| Nom. inner shield DCR | 12.3 Ohm/1000ft (40.4 Ohm/km) |
| Nom. capacitance cond-to-cond | 50 pF/ft (160 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 95 pF/ft (310 pF/m) |
| Nom. characteristic impedence | 50 Ohm |
| Nom. inductance | 0.095 µH/ft (0.31 µH/m) |
| Nom. velocity of prop. | 60% |
| Max. current | 4.8 Amps per Conductor at 30ºC |
| UL temperature | 80°C |
| Operating | -20°C to +80°C |
| Stationary min. bend radius | 1.73 in (43.9 mm) |
| Installation min. bend radius | 1.73 in |
| Max Pull Tension | 36 lbs (16 kg) |
| Bulk cable weight | 30 lbs/1000ft |
| Flammability / reaction to fire | UL1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 9406 T35U1000 UPC 612825240020 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.