Belden 9409 060, Power Limited Tray Cable 1PR 18 AWG 300V PVC, Chrome Jacket

SKU:Belden 9409 060
● In stock
Description
Belden 9409 060 is an instrumentation PLTC tray cable designed for signal and control wiring in industrial environments. It features 1 pair of 18 AWG (19x30) TC - Tinned Copper conductors with PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride outer jacket in Chrome. This unshielded, stranded cable includes a ripcord to simplify jacket removal and has a UL Voltage Rating of 300 V (PLTC, CMG).
Belden 9409 060 Key Features
- 1 pair construction with 18 AWG conductors for instrumentation signal and control wiring.
- 19x30 stranded TC - Tinned Copper conductors for flexible routing and termination.
- PVC - Polyvinyl Chloride insulation with Black & Red color code for conductor identification.
- PVC - Polyvinyl Chloride outer jacket in Chrome with a ripcord for easier jacket removal.
- Unshielded design (Shield: No Shield) with no armor (Armor: No).
- UL Voltage Rating: 300 V (PLTC, CMG).
Belden 9409 060 Applications
- Use for instrumentation wiring requiring reliable signal and control connections in industrial environments.
- Connect sensors to carry measurement signals in common analog and control circuits.
- Support valve wiring for control and signal connections in industrial control systems.
- Connect positioners to support signal and control wiring in automation setups.
- Run 4-20mA circuits in analog instrumentation and control loops.
- Run 0-10V circuits in common analog and control applications.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 1 |
| Element type | pair(s) |
| Insulation thickness (nom.) | 0.018 in (0.46 mm) |
| Insulation diameter (nom.) | 0.081 in (2.1 mm) |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Overall cable diameter (nom.) | 0.236 in (5.99 mm) |
| Bulk cable weight | 26 lbs/1000ft |
| Nom. conductor DCR | 7.2 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 26 pF/ft (85 pF/m) |
| Max. current | 5 Amps per Conductor at 25ºC |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 2.4 in (61 mm) |
| Bend radius (installation min.) | 2.4 in (61 mm) |
| Max Pull Tension | 49 lbs (22 kg) |
| Thermocouple | No |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9409 060100; 9409 060250; 9409 060500; 9409 0601000; 9409 0602500 UPC 612825240174; 9409 0605000 UPC 612825240181 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.