Belden 9410 060 is an instrumentation Power Limited Tray Cable (PLTC) built with 1 pair 16 AWG (19x29) TC - Tinned Copper conductors and PVC - Polyvinyl Chloride insulation with a PVC - Polyvinyl Chloride outer jacket. This unshielded twisted pair cable is rated 300 V (PLTC, CMG) and supports control and signal applications including instrumentation, sensors, valves, positioners, 4-20mA, and 0-10V. It is designed for an operating temperature range of -30°C to +105°C and features a Chrome jacket with a ripcord to help simplify jacket removal during installation.
Belden 9410 060 Key Features
- Instrumentation Power Limited Tray Cable (PLTC) construction for control and signal wiring.
- 1 pair 16 AWG (19x29) stranded TC - Tinned Copper conductors.
- PVC - Polyvinyl Chloride insulation and PVC - Polyvinyl Chloride outer jacket.
- Unshielded twisted pair design (No Shield).
- UL voltage rating: 300 V (PLTC, CMG).
- Operating temperature: -30°C to +105°C.
- Chrome jacket with ripcord: Yes.
Belden 9410 060 Applications
- Supports instrumentation wiring for control and signal connections.
- Connects sensors in control and monitoring systems.
- Wires valves and positioners in automation and process control setups.
- Handles signal types including 4-20mA and 0-10V.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Elements | 1 |
| Element type | Pair(s) |
| Conductor Material | TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Armor | No |
| Thermocouple | No |
| Insulation thickness (nom.) | 0.0185 in (0.470 mm) |
| Insulation diameter (nom.) | 0.096 in (2.4 mm) |
| Insulation color code | Black & Red |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Overall cable diameter (nom.) | 0.260 in (6.60 mm) |
| Bulk cable weight | 35 lbs/1000ft |
| Nom. conductor DCR | 4.5 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 31 pF/ft (100 pF/m) |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Max. current | 6.2 Amps per Conductor at 25°C |
| UL temperature | 105°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max Pull Tension | 80 lbs (36 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9410 060100; 9410 060250; 9410 060500; 9410 0601000 UPC 612825240211; 9410 0602500 UPC 612825240228 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?