Belden 9412 060, Power Limited Tray Cable 1PR 12 AWG 300V PVC, Chrome Jacket

Description
Belden 9412 060 is an instrumentation Power Limited Tray Cable (PLTC) built with 1 pair 12 AWG stranded (65x30) TC - Tinned Copper conductors and PVC - Polyvinyl Chloride insulation. This unshielded 300 V (PLTC) cable uses a PVC - Polyvinyl Chloride outer jacket in Chrome and includes a ripcord for easier jacket removal. It is rated for UL temperature 105°C with an operating temperature range of -30°C to +105°C, and it is listed for indoor/outdoor use with sunlight resistance.
Belden 9412 060 Key Features
- 1 pair construction with 12 AWG stranded (65x30) TC - Tinned Copper conductors for instrumentation signal and control wiring.
- Unshielded design (No Shield) with no armor.
- UL voltage rating: 300 V (PLTC).
- PVC - Polyvinyl Chloride insulation and PVC - Polyvinyl Chloride outer jacket with Chrome jacket color.
- Ripcord: Yes, for easier jacket removal during installation.
- Environmental suitability: indoor/outdoor, outdoor, sunlight resistance.
- Flammability / reaction to fire: UL 1685 UL Loading, T-29-520, IEEE 1202, FT4.
- NEC / UL compliance: Article 725, Article 727, CL3R, ITC, PLTC.
Belden 9412 060 Applications
- Supports instrumentation wiring where reliable signal and control connections are required.
- Connects sensors in control and monitoring systems.
- Suitable for wiring valves in automated or controlled processes.
- Provides consistent control signaling for positioners.
- Designed for 4-20mA signal loops used in industrial measurement and control.
- Handles 0-10V control signals in automation and instrumentation circuits.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 1 |
| Element type | Pair(s) |
| Conductor Type | Stranded Conductor |
| Insulation thickness (nom.) | 0.025 in (0.64 mm) |
| Insulation diameter (nom.) | 0.143 in (3.63 mm) |
| Insulation color code | Black & Red |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Overall cable diameter (nom.) | 0.370 in (9.40 mm) |
| Bulk cable weight | 77 lbs/1000ft |
| Nom. conductor DCR | 1.78 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 25 pF/ft (82 pF/m) |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 10.3 Amps per Conductor at 25ºC |
| Operating temperature | -30°C to +105°C |
| UL temperature | 105°C |
| Temperature table notes | AWM 80°C |
| Stationary min. bend radius | 3.7 in (94 mm) |
| Installation min. bend radius | 3.7 in (94 mm) |
| Max Pull Tension | 169 lbs (76.7 kg) |
| Thermocouple | No |
| AWM compliance | AWM 2464 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9412 060100; 9412 060250; 9412 060500 UPC 612825240310; 9412 0601000 UPC 612825240297; 9412 0602500 UPC 612825240303 |
| Priced Per | FT |