Belden 9462 060U, Multi Pair Cable 1 Pair 22 AWG PVC Jacket, Chrome Jacket

Description
Belden 9462 060U is a 1 pair, 22 AWG multi pair cable designed for audio, control, and instrumentation signal transmission. It uses 2 stranded conductors (7x30) of tinned copper with PVC insulation, plus an overall Beldfoil® shield to support noise rejection. The cable has a chrome PVC outer jacket and carries a 300 V (CMG) / 300 V (UL AWM 2464) rating for indoor general-purpose installations.
Belden 9462 060U Key Features
- 1 pair construction with 2 stranded conductors (7x30) for flexible signal wiring.
- 22 AWG tinned copper conductors with PVC insulation.
- Overall Beldfoil® tape shield with a drain wire for noise rejection.
- Chrome PVC outer jacket with NEC CMG rating for indoor general-purpose installations.
- Electrical performance includes 16 Ohm/1000ft DCR and 50 pF/ft capacitance Cond-to-Cond.
- Voltage rating: 300 V (CMG), 300 V (UL AWM 2464).
Belden 9462 060U Applications
- Support low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation signal paths.
- Use it for low voltage digital control (24v, …) where consistent signal transmission is needed.
- Run line level audio connections in installed audio and signal routing.
- Choose it for computer communication signal wiring.
- Install it in panel wiring for indoor general-purpose wiring layouts.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor count | 1 pair |
| Number of Conductors | 2 |
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.0155 in (0.394 mm) |
| Insulation nominal diameter | 0.060 in (1.5 mm) |
| Insulation color code | Black, Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Shield notes | Foil-Out |
| Drainwire type | 22 AWG (7x30) TC |
| Shield construction | Overall Shield & drain |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Chrome |
| Jacket nominal thickness | 0.035 in (0.89 mm) |
| Overall cable diameter (nominal) | 0.194 in (4.93 mm) |
| Jacket nominal diameter | 0.194 in (4.93 mm) |
| Bulk cable weight | 19 lbs/1000ft |
| Capacitance, Cond-to-other (conds + Shield) | 90 pF/ft (300 pF/m) |
| Characteristic impedence (nominal) | 36 Ohm |
| Inductance (nominal) | 0.19 µH/ft (0.62 µH/m) |
| Max. current | 3 Amps per Conductor at 25ºC |
| UL temperature | 80°C |
| Operating temperature | -30°C to +80°C |
| Bend radius (stationary min.) | 1.9 in (48 mm) |
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | Article 800, CMG |
| NEC rating | NEC CMG |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 9462 060U1000 UPC 612825253440 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.