Belden 9486 010, Power Limited Tray Cable 1 Pair 18 AWG 600V PVC, Black Jacket

SKU:Belden 9486 010
● In stock
Description
Belden 9486 010 is a VNTC control instrumentation and control cable with 1 pair 18 AWG (19x32) tinned copper conductors and PVC/Nylon insulation, finished with a black PVC outer jacket. This unshielded 2 conductor cable includes a ripcord for easier jacket removal during installation. It supports 600V and carries a UL voltage rating of 600 V (TC), 150 V (NPLF) for control and instrumentation wiring needs.
Belden 9486 010 Key Features
- VNTC control construction with 1 element configured as pair(s).
- 1 pair, 2 conductor design using 18 AWG (19x32) tinned copper conductors.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with black & red color code.
- Black PVC - Polyvinyl Chloride outer jacket.
- Unshielded design with ripcord: Yes.
- Voltage range: 600V; UL voltage rating: 600 V (TC), 150 V (NPLF).
- UL temperature: 90°C Dry, 90°C Wet; Operating: Wet/Dry: -30°C to 90°C.
Belden 9486 010 Applications
- Designed for industrial control installations where instrumentation and control wiring is required.
- Intended for routing through raceways, cable trays, and ducts in industrial environments.
- Suitable for digital control systems and related control wiring needs.
- Works with instruments (4-20ma, 0-10v, ...) where instrumentation signals are present.
- Supports low voltage digital control (24v, …) applications as listed.
- Suitable for encoder connections in control and automation setups.
- Used for control circuits where consistent control wiring is needed.
- Fits distributed control applications where control wiring is deployed across multiple points.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Product type | VNTC Control |
| Number of elements | 1 |
| Element type | Pair(s) |
| Number of Conductors | 2 Conductor |
| Conductor size | 18 AWG |
| Conductor stranding | 19x32 |
| Conductor Material | Tinned Copper |
| Insulation Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color Code | Black & Red |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Ripcord | Yes |
| Shield | Unshielded |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| Nom. thickness (insulation) | 0.016 in (0.41 mm) |
| Nom. insulation diameter | 0.088 in (2.2 mm) |
| Nom. thickness (outer jacket) | 0.048 in (1.2 mm) |
| Nom. diameter | 0.275 in (6.99 mm) |
| Bulk cable weight | 40 lbs/1000ft |
| Nom. conductor DCR | 7.29 Ohm/1000ft |
| Nom. inductance | 0.23 µH/ft (0.75 µH/m) |
| Max. current | 15 Amps per Conductor at 25ºC |
| Bend radius (stationary min.) | 1.08 in (27.4 mm) |
| Bend radius (installation min.) | 1.35 in (34.3 mm) |
| Max Pull Tension | 50 lbs (23 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9486 010100; 9486 010250; 9486 010500; 9486 0101000 UPC 612825253778 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.