Belden 9492 060, Power Limited Tray Cable 1 Triads 20 AWG 300V PVC, Chrome Jacket

SKU:Belden 9492 060
● In stock
Description
Belden 9492 060 is an instrumentation Power Limited Tray Cable (PLTC) built with 1 triad 20 AWG (19x32) TC - Tinned Copper stranded conductors and PVC - Polyvinyl Chloride insulation and jacket. It is rated 300 V (PLTC, CMG) and uses an unshielded, twisted triad construction. This cable includes a ripcord for easier jacket removal and is listed for Indoor/Outdoor use with Sunlight Resistance. It meets Article 725, Article 727, Article 800, UL 1685 UL Loading, FT4, T-29-520, and IEEE 1202.
Belden 9492 060 Key Features
- Instrumentation Power Limited Tray Cable (PLTC) design for signal and control wiring in instrumentation circuits.
- 1 triad 20 AWG (19x32) TC - Tinned Copper stranded conductor construction.
- PVC - Polyvinyl Chloride insulation and PVC - Polyvinyl Chloride outer jacket.
- Unshielded twisted triad construction (No Shield).
- Includes a ripcord to support easier jacket removal during installation.
- Rated 300 V (PLTC, CMG).
- Environmental suitability includes Indoor/Outdoor use and Sunlight Resistance.
- Compliance includes Article 725, Article 727, Article 800, UL 1685 UL Loading, FT4, T-29-520, and IEEE 1202.
Belden 9492 060 Applications
- Use in instrumentation circuits where reliable signal and control wiring is needed.
- Support sensor wiring in instrumentation systems.
- Connect valves used in control and instrumentation circuits.
- Handle positioner wiring for instrumentation and control setups.
- Serve RTD circuits in instrumentation applications.
- Run 4-20mA instrumentation loops.
- Carry 0-10V control signal wiring.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Elements | Triad(s) |
| No. of elements | 1 |
| Conductor Type | Stranded Conductor |
| Color Code | ICEA Chart E1 |
| Armor | No |
| Thermocouple | No |
| Insulation thickness (nom.) | 0.018 in (0.46 mm) |
| Insulation diameter (nom.) | 0.072 in (1.8 mm) |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Overall cable diameter (nom.) | 0.229 in (5.82 mm) |
| Jacket Color | Chrome |
| Bulk cable weight | 28 lbs/1000ft |
| Nom. conductor DCR | 11.3 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. inductance | 0.19 µH/ft (0.62 µH/m) |
| Max. current | 3.8 Amps per Conductor at 25ºC |
| UL temperature | 105°C |
| Operating | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 2.3 in (58 mm) |
| Bend radius (installation min.) | 2.3 in (58 mm) |
| Max Pull Tension | 45 lbs (20 kg) |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9492 060100; 9492 060250; 9492 060500; 9492 0601000 UPC 612825253891; 9492 0602500 UPC 612825253907; 9492 0605000 UPC 612825253914 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.