Belden 9493 060, Power Limited Tray Cable 1 Triads 18 AWG 300V PVC, Chrome Jacket

SKU:Belden 9493 060
● In stock
Description
Belden 9493 060 is an instrumentation Power Limited Tray Cable (PLTC) built with 1 triad 18 AWG (19x30) TC - Tinned Copper stranded conductors and a PVC - Polyvinyl Chloride outer jacket in Chrome. This unshielded (No Shield), twisted triad cable uses PVC - Polyvinyl Chloride insulation with ICEA Chart E1 color coding and includes a ripcord for easier jacket removal. It is rated 300 V (PLTC, CMG) with a UL temperature of 105°C and is listed for Indoor/Outdoor, Sunlight Resistance, and Burial environments.
Belden 9493 060 Key Features
- Instrumentation Power Limited Tray Cable (PLTC) construction with 1 triad 18 AWG (19x30) stranded TC - Tinned Copper conductors.
- Unshielded (No Shield) twisted triads design for signal and control wiring.
- PVC - Polyvinyl Chloride insulation with ICEA Chart E1 color code.
- PVC - Polyvinyl Chloride outer jacket in Chrome with a ripcord for easier jacket removal.
- Rated 300 V (PLTC, CMG) with a UL temperature of 105°C.
- Environmental suitability includes Indoor/Outdoor, Sunlight Resistance, and Burial.
Belden 9493 060 Applications
- Use for instrumentation wiring where consistent signal and control connections are needed.
- Connect sensors in control and monitoring circuits.
- Wire valves in automated control systems.
- Support positioner connections for control and feedback functions.
- Run RTD circuits where temperature measurement signals are carried back to instrumentation.
- Implement 4-20mA signal loops used for industrial process measurement and control.
- Handle 0-10V control and signal wiring in instrumentation and automation systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor element | Triad(s) |
| Number of elements | 1 |
| Conductor Type | Stranded Conductor |
| Pairing | Twisted triads |
| Insulation thickness (nom.) | 0.019 in (0.48 mm) |
| Insulation diameter (nom.) | 0.082 in (2.1 mm) |
| Separator | PP - Polypropylene Tape |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Overall cable diameter (nominal) | 0.265 in (6.73 mm) |
| Nom. conductor DCR | 7.2 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 31.8 pF/ft (104 pF/m) |
| Nom. inductance | 0.15 µH/ft (0.49 µH/m) |
| Max. current | 5 Amps per Conductor at 25ºC |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max Pull Tension | 74 lbs (34 kg) |
| Bulk cable weight | 40 lbs/1000ft |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9493 060100; 9493 060250; 9493 060500; 9493 0601000; 9493 0602500 UPC 612825253945; 9493 0605000 UPC 612825253952 |
| Priced Per | FT |