Belden 9494 060, Power Limited Tray Cable 1 Triads 16 AWG 300V PVC, Chrome Jacket

SKU:Belden 9494 060
● In stock
Description
Belden 9494 060 is an instrumentation Power Limited Tray Cable (PLTC) with 1 triad of 16 AWG (19x29) TC - Tinned Copper conductors. It features PVC - Polyvinyl Chloride insulation and a Chrome PVC - Polyvinyl Chloride outer jacket with a ripcord. This unshielded triad cable is rated 300 V (PLTC, CMG) and supports a max. current of 6.2 Amps per Conductor at 25°C. It is listed for Indoor/Outdoor use with Sunlight Resistance.
Belden 9494 060 Key Features
- 1 triad(s) construction with 16 AWG stranded conductors (19x29) made from TC - Tinned Copper.
- PVC - Polyvinyl Chloride insulation and a Chrome PVC - Polyvinyl Chloride outer jacket.
- Unshielded design (No Shield) with no armor.
- 300 V (PLTC, CMG) UL voltage rating.
- Max. current of 6.2 Amps per Conductor at 25°C.
- Indoor/Outdoor environmental suitability with Sunlight Resistance.
Belden 9494 060 Applications
- Use for instrumentation wiring where consistent signal transmission is required.
- Connect sensors in control and monitoring systems.
- Wire valves in automation and process control setups.
- Support positioner connections for control feedback and positioning signals.
- Run RTD circuits for temperature measurement and monitoring.
- Carry 4-20mA signals commonly used in industrial instrumentation loops.
- Handle 0-10V signal wiring for analog control and monitoring.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 1 |
| Element type | Triad(s) |
| Conductor Type | Stranded Conductor |
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.097 in (2.5 mm) |
| Color Code | ICEA Chart E1 |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Overall cable diameter (nom.) | 0.293 in (7.44 mm) |
| Bulk cable weight | 51 lbs/1000ft |
| Conductor DCR (nom.) | 4.5 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 29 pF/ft (95 pF/m) |
| Inductance (nom.) | 0.14 µH/ft (0.46 µH/m) |
| Stationary min. bend radius | 2.8 in (71 mm) |
| Installation min. bend radius | 2.8 in (71 mm) |
| Max Pull Tension | 120 lbs (54 kg) |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9494 060100; 9494 060250; 9494 060500; 9494 0601000; 9494 0602500 UPC 612825253983 |