Belden 9495 060, Power Limited Tray Cable 1 Triads 14 AWG 300V PVC, Chrome Jacket

SKU:Belden 9495 060
● In stock
Description
Belden 9495 060 is an instrumentation PLTC tray cable built with 1 triad 14 AWG stranded (42x30) TC - Tinned Copper conductors and a PVC - Polyvinyl Chloride insulation/jacket system. This unshielded cable is rated 300 V (PLTC, CMG) and features a Chrome PVC - Polyvinyl Chloride outer jacket with a ripcord. It supports an operating temperature range of -30°C to +105°C and is listed for Indoor/Outdoor use, including Sunlight Resistance and Burial.
Belden 9495 060 Key Features
- Instrumentation PLTC tray cable construction with 1 triad 14 AWG stranded (42x30) TC - Tinned Copper conductors.
- Unshielded design (No Shield) for control and signal wiring where shielding is not required.
- 300 V (PLTC, CMG) UL Voltage Rating for applicable installations.
- PVC - Polyvinyl Chloride insulation and Chrome PVC - Polyvinyl Chloride outer jacket with Ripcord: Yes for easier stripping.
- Operating temperature: -30°C to +105°C; UL temperature: 105°C.
- Environmental suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial.
Belden 9495 060 Applications
- Use for instrumentation wiring for control and signal connections in industrial systems.
- Connect sensors where a dedicated signal cable is needed for measurement and monitoring circuits.
- Support valve wiring for control signals between devices and control equipment.
- Enable positioner connections for transmitting control signals in automation setups.
- Wire RTD circuits where signal wiring is required for temperature measurement loops.
- Run 4-20mA signal loops used in instrumentation and process control systems.
- Implement 0-10V signal wiring for analog control and monitoring signals.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 1 |
| Element type | Triad(s) |
| Conductor size | 14 AWG |
| Stranding | 42x30 |
| Material | TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation nom. thickness | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.119 in (3.02 mm) |
| Color Code | Black , White , Red |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Chrome |
| Jacket nom. thickness | 0.042 in (1.1 mm) |
| Armor | No |
| Thermocouple | No |
| Nom. diameter | 0.355 in (9.02 mm) |
| Overall cable diameter (nominal) | 0.355 in (9.02 mm) |
| Bulk cable weight | 82 lbs/1000ft |
| Nom. conductor DCR | 2.8 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 27 pF/ft (89 pF/m) |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 8 Amps per Conductor at 25°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 3.6 in (91 mm) |
| Bend radius (installation min.) | 3.6 in (91 mm) |
| Max Pull Tension | 160 lbs (73 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, T-29-520, IEEE 1202, FT4 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9495 060100; 9495 060250; 9495 060500 UPC 612825254010 ; 9495 0601000 UPC 612825253990; 9495 0602500 UPC 612825254003 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.