Belden 9504 060U, Computer Cable 4 Pair 24 AWG PVC FS PVC Chrome

SKU:Belden 9504 060U1000
● In stock
Description
Belden 9504 060U is a 4 twisted pair 24 AWG EIA RS-232 computer cable designed for computer communications and low voltage signal transmission. It uses 24 AWG Stranded (7x32) TC - Tinned Copper conductors with SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation and an overall Beldfoil® tape shield with 100% coverage. A 24 AWG (7x32) TC drainwire is included, and the cable is finished with a Chrome PVC - Polyvinyl Chloride jacket for indoor installations.
Belden 9504 060U Key Features
- 4 twisted pairs with 24 AWG Stranded (7x32) TC - Tinned Copper conductors for EIA RS-232 computer communications and low voltage signal transmission.
- Overall Beldfoil® tape shield with 100% coverage to support noise protection in signal wiring.
- Includes a 24 AWG (7x32) TC drainwire as part of the overall shield and drain construction.
- SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation paired with a PVC - Polyvinyl Chloride jacket for indoor environmental suitability.
- UL voltage rating: 300 V (CMG), 300 V (UL AWM 2464).
- Operating temperature: -30°C to +80°C; UL temperature: 80°C.
Belden 9504 060U Applications
- Use in RS-232 applications where consistent computer communications and low voltage signal transmission are required.
- Install for panel wiring in control panels and similar low voltage signal routing.
- Support line level audio connections where shielded signal cabling is needed.
- Carry low voltage analog signals (4-20ma, 0-10v, ...) in instrumentation and control signal paths.
- Handle low voltage digital control (24v, …) in control and signaling circuits.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 4 twisted pairs |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | SR-PVC - Polyvinyl Chloride (Semi-Rigid) |
| Nom. thickness (insulation) | 0.011 in (0.28 mm) |
| Nom. insulation diameter | 0.044 in (1.1 mm) |
| Color Code | Black & Red, Black & White, Black & Green, Black & Blue |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Chrome |
| Nom. thickness (jacket) | 0.032 in (0.81 mm) |
| Nom. diameter | 0.259 in (6.58 mm) |
| Overall shield | Beldfoil® |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Nom. conductor DCR | 28.8 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 50 pF/ft (160 pF/m) |
| Nom. velocity of prop. | 60% |
| Max. current | 2.2 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 16.19 Ohm/1000ft (53.12 Ohm/km) |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max Pull Tension | 50 lbs (23 kg) |
| Bulk cable weight | 32 lbs/1000ft |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464, AWM I/II A |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 89504, 82504 |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9504 060U1000 UPC 612825254249 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.