Belden 9506 060, Multi Conductor Computer Cable 6 Pair 24 AWG PVC

SKU:Belden 9506 060
● In stock
Description
Belden 9506 060 is a Computer EIA RS-232 Cable built with 6 twisted pairs of 24 AWG Stranded (7x32) TC - Tinned Copper conductors and semi-rigid SR-PVC insulation. It features an overall Beldfoil® tape shield with 100% coverage plus a 24 AWG (7x32) TC drain wire to support grounding and help reduce EMI. The PVC jacket in Chrome is designed for Indoor use and is rated UL Voltage Rating: 300 V (CMG), 300 V (UL AWM 2464). Key electrical and handling characteristics include Nom. capacitance Cond-to-Cond: 30 pF/ft (98 pF/m), Operating temperature: -30°C to +80°C, and Bend Radius (installation min.): 2.9 in (74 mm).
Belden 9506 060 Key Features
- 6 twisted pairs of 24 AWG Stranded (7x32) TC - Tinned Copper conductors for multi-pair signal wiring.
- Semi-rigid SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation with color code: Black & Red, Black & White, Black & Green, Black & Blue, Black & Yellow, Black & Brown.
- Overall Beldfoil® tape shield with 100% coverage and Bi-Laminate (Alum+Poly) construction, plus a 24 AWG (7x32) TC drain wire.
- PVC - Polyvinyl Chloride jacket in Chrome for Indoor installations.
- UL Voltage Rating: 300 V (CMG), 300 V (UL AWM 2464).
- Operating temperature: -30°C to +80°C; UL temperature: 80°C.
Belden 9506 060 Applications
- Commonly used in RS-232 applications where multi-pair signal connections are needed.
- Supports computer communications links that require consistent low-voltage signal transmission.
- Suitable for low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation wiring.
- Can be applied to low voltage digital control (24v, …) circuits in automation and control panels.
- Used for line level audio signal runs where shielded multi-conductor cabling is required.
- Used for panel wiring to organize and route multiple signal pairs within enclosures.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Cable type | Computer EIA RS-232 Cable |
| Number of elements | 6 twisted pairs |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Shield Type | Tape |
| Shield construction | Overall Shield & drain |
| Jacket thickness (nom.) | 0.032 in (0.81 mm) |
| Overall cable diameter (nominal) | 0.289 in (7.34 mm) |
| Bulk cable weight | 44 lbs/1000ft |
| Plenum number | 82506 |
| Nom. conductor DCR | 28.8 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 50 pF/ft (160 pF/m) |
| Nom. velocity of prop. | 60% |
| Max. current | 1.96 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 16.19 Ohm/1000ft (53.12 Ohm/km) |
| Bend radius (stationary min.) | 2.9 in (74 mm) |
| Bend radius (installation min.) | 2.9 in (74 mm) |
| Max Pull Tension | 72 lbs (33 kg) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4 |
| NEC / UL compliance | Article 800, CMG |
| CEC / C(UL) compliance | CMG |
| AWM compliance | AWM 2464, AWM I/II A |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 9506 060100 UPC 612825254386; 9506 060250; 9506 060500 UPC 612825254409; 9506 0601000 UPC 612825254393; 9506 0605000 UPC 612825254416 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.