Belden 9512 060, Power Limited Tray Cable 2C 22 AWG 300V PVC, Chrome Jacket

SKU:Belden 9512 060
● In stock
Description
Belden 9512 060 is an instrumentation PLTC cable built with 2 pair 22 AWG (7x30) TC - Tinned Copper conductors and PVC insulation with ICEA Chart E2 color coding. It features an overall Beldfoil® shield with 100% coverage and a 22 AWG (7x30) TC drainwire to help reduce electrical noise. The PVC outer jacket includes a ripcord and is finished in Chrome for field identification. UL Voltage Rating is 300 V (PLTC, CMG) with a UL temperature rating of 105°C and an operating range of -30°C to +105°C.
Belden 9512 060 Key Features
- 2 pair construction with 22 AWG (7x30) TC - Tinned Copper conductors for instrumentation signal wiring.
- PVC - Polyvinyl Chloride insulation with ICEA Chart E2 color code for consistent conductor identification.
- Overall Beldfoil® shield (Tape, Bi-Laminate (Alum+Poly)) with 100% coverage and a 22 AWG (7x30) TC drainwire to help reduce electrical noise.
- PVC - Polyvinyl Chloride outer jacket with ripcord and Chrome jacket color to support easier installation and field identification.
- UL Voltage Rating: 300 V (PLTC, CMG); UL temperature: 105°C; operating: -30°C to +105°C.
Belden 9512 060 Applications
- Use in instrumentation circuits where reliable signal transmission is needed for control and monitoring.
- Support sensors, valves, and positioners in control systems where consistent signal wiring is required.
- Carry 4-20mA and 0-10V signal runs used in common instrumentation and control loops.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Spec Name | Value |
| Elements | Pair(s) |
| No. of elements | 2 |
| Insulation nominal thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.062 in (1.6 mm) |
| Jacket nominal thickness | 0.042 in (1.1 mm) |
| Overall cable diameter (nominal) | 0.295 in (7.49 mm) |
| Bulk cable weight | 38 lbs/1000ft |
| Armor | No |
| Thermocouple | No |
| Shield | Yes - this has a shield |
| Shield DCR (nom.) | 11.54 Ohm/1000ft (37.86 Ohm/km) |
| Nom. conductor DCR | 18.2 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 26 pF/ft (85 pF/m) |
| Capacitance, Cond-to-other (conds + Shield) (nom.) | 45 pF/ft (150 pF/m) |
| Inductance (nom.) | 0.21 µH/ft (0.69 µH/m) |
| Temperature table notes | AWM 80°C |
| Stationary min. bend radius | 3.0 in (76 mm) |
| Installation min. bend radius | 3.0 in (76 mm) |
| Max Pull Tension | 45 lbs (20 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9512 060100; 9512 060250; 9512 060500 UPC 612825254645; 9512 0601000 UPC 612825254638; 9512 0605000 UPC 612825254652 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.