Belden 9534 060, Multi Conductor Computer Cable 4 pair 24 AWG PVC

Description
Belden 9534 060 is a computer EIA RS-232 Cable with 4 conductors of 24 AWG Stranded (7x32) TC - Tinned Copper and SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation. An overall tape shield with 100% coverage plus a 24 AWG (7x32) TC drainwire helps reduce noise in signal and control circuits. This cable has a PVC - Polyvinyl Chloride jacket in Chrome and a 0.184 in (4.67 mm) nominal diameter. UL Voltage Rating is 300 V (CMG), 300 V (UL AWM 2464).
Belden 9534 060 Key Features
- 4-conductor construction with 24 AWG Stranded (7x32) TC - Tinned Copper conductors.
- SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation with color code: Black, White, Red, Green.
- Overall tape shield made from Bi-Laminate (Alum+Poly) with 100% coverage, plus a 24 AWG (7x32) TC drainwire.
- PVC - Polyvinyl Chloride jacket in Chrome with a 0.184 in (4.67 mm) nominal diameter.
- UL Voltage Rating: 300 V (CMG), 300 V (UL AWM 2464).
Belden 9534 060 Applications
- Use in RS-232 applications where a shielded computer EIA RS-232 Cable is needed for signal transmission.
- Support computer communications that benefit from an overall shield and drainwire to help reduce noise.
- Carry low voltage analog signals (4-20mA, 0-10V, ...) in control and instrumentation-style signal runs.
- Handle low voltage digital control (24V, …) where consistent signal handling is required.
- Connect line level audio signals.
- Use for panel wiring in indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Jacket thickness (nom.) | 0.032 in (0.81 mm) |
| Bulk cable weight | 18 lbs/1000ft |
| Conductor DCR (nom.) | 25 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 33 pF/ft (110 pF/m) |
| Capacitance, Cond-to-other (nom.) | 65 pF/ft (210 pF/m) |
| Max. current | 1.8 Amps per Conductor at 25ºC |
| Outer shield DCR (nom) | 18 Ohm/1000ft (59 Ohm/km) |
| Operating temperature | -30°C to +80°C |
| UL temperature | 60°C (UL CMG); 80°C (UL AWM 2464) |
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max Pull Tension | 28 lbs (13 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | Article 800, CMG |
| CEC / C(UL) compliance | CMG |
| AWM compliance | AWM 2464 |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9534 060100, 9534 060250, 9534 060500, 9534 0601000, UPC 612825255130 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.