Belden 9535 060, Multi Conductor Computer Cable 5C 24 AWG PVC

SKU:Belden 9535 060
● In stock
Description
Belden 9535 060 is a 5-conductor 24 AWG computer EIA RS-232 cable with a PVC jacket in Chrome for indoor installations. It uses 24 AWG stranded (7x32) TC - Tinned Copper conductors with SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation. The cable includes an overall Beldfoil® shield (100% coverage) with a 24 AWG (7x32) TC drainwire to help reduce noise. Electrical characteristics include UL Voltage Rating: 300 V (CMG), 300 V (UL AWM 2464) and UL temperature: 60°C (UL CMG); 80°C (UL AWM 2464).
Belden 9535 060 Key Features
- 5-conductor 24 AWG construction supports computer communications and low-voltage control wiring.
- 24 AWG stranded (7x32) TC - Tinned Copper conductors with SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation.
- Overall Beldfoil® shield (100% coverage) with a 24 AWG (7x32) TC drainwire to help reduce noise.
- PVC - Polyvinyl Chloride jacket in Chrome for indoor installations.
- UL Voltage Rating: 300 V (CMG), 300 V (UL AWM 2464).
- UL temperature: 60°C (UL CMG); 80°C (UL AWM 2464).
Belden 9535 060 Applications
- Use it for RS-232 applications where consistent signal transmission is needed in computer communications links.
- Choose it for computer communications wiring where a shielded construction is preferred for noise reduction.
- Apply it to low voltage analog signals (4-20mA, 0-10V, ...) in control and instrumentation circuits.
- Support low voltage digital control (24V, …) connections in control wiring with this cable.
- Install it for line level audio runs where a shielded cable is desired.
- Use it in panel wiring to route signals within control panels and equipment enclosures.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor Material | TC - Tinned Copper |
| Conductor stranding | 7x32 |
| Insulation Material | SR-PVC - Polyvinyl Chloride (Semi-Rigid) |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Color Code | Black, White, Red, Green, Brown |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Chrome |
| Jacket thickness (nom.) | 0.032 in (0.81 mm) |
| Overall cable diameter (nominal) | 0.189 in (4.80 mm) |
| Bulk cable weight | 22 lbs/1000ft |
| Nom. conductor DCR | 25 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 65 pF/ft (210 pF/m) |
| Max. current | 1.8 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 18 Ohm/1000ft (59 Ohm/km) |
| Operating temperature | -30°C to +80°C |
| Bend radius (stationary min.) | 2.3 in (58 mm) |
| Bend radius (installation min.) | 2.3 in (58 mm) |
| Max Pull Tension | 33 lbs (15 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | Article 800, CMG |
| CEC / C(UL) compliance | CMG |
| AWM compliance | AWM 2464 |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9535 060100, 9535 060250, 9535 060500, 9535 0601000, UPC 612825255178 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.