Belden 9537 060, Multi Conductor Computer Cable 7C 24 AWG PVC

SKU:Belden 9537 060
● In stock
Description
Belden 9537 060 is a multi-conductor computer EIA RS-232 cable designed for control and communications wiring. It is built with 7 x 24 AWG stranded (7x32) TC - tinned copper conductors, SR-PVC - polyvinyl chloride (semi-rigid) insulation, and a PVC - polyvinyl chloride jacket in Chrome. For noise reduction, it includes an overall Beldfoil® shield with 100% coverage and a 24 AWG (7x32) TC drainwire. Key ratings and limits include UL voltage rating: 300 V (CMG), 300 V (UL AWM 2464) and operating temperature: -30°C to +80°C.
Belden 9537 060 Key Features
- 7 conductors with 24 AWG stranded (7x32) TC - tinned copper for control and communications wiring.
- SR-PVC - polyvinyl chloride (semi-rigid) insulation with color code: Black, White, Red, Green, Brown, Blue, Orange.
- Overall Beldfoil® shield (100% coverage) with tape construction and bi-laminate (Alum+Poly) material, plus a 24 AWG (7x32) TC drainwire.
- PVC - polyvinyl chloride jacket in Chrome for indoor installations.
- UL voltage rating: 300 V (CMG), 300 V (UL AWM 2464).
- Operating temperature: -30°C to +80°C.
Belden 9537 060 Applications
- Use in RS-232 applications where consistent signal transmission is needed.
- Support computer communications connections in control and communications wiring setups.
- Handle low voltage analog signals (4-20mA, 0-10V, ...) in control and communications wiring.
- Run low voltage digital control (24V, …) signal wiring.
- Carry line level audio signal runs where shielded signal wiring is required.
- Install for panel wiring in indoor environments.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor DCR (nom.) | 25 Ohm/1000ft |
| Shield DCR (nom.) | 18 Ohm/1000ft (59 Ohm/km) |
| Capacitance, Cond-to-Cond (nom.) | 33 pF/ft (110 pF/m) |
| Capacitance, Cond-to-other (conds + Shield) (nom.) | 65 pF/ft (210 pF/m) |
| Max. current | 1.5 Amps per conductor at 25ºC |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Jacket thickness (nom.) | 0.032 in (0.81 mm) |
| Overall cable diameter (nom.) | 0.209 in (5.31 mm) |
| Bulk cable weight | 28 lbs/1000ft |
| UL temperature | 60°C (UL CMG);80°C (UL AWM 2464) |
| Bend radius (stationary min.) | 2.5 in (64 mm) |
| Bend radius (installation min.) | 2.5 in (64 mm) |
| Max Pull Tension | 44 lbs (20 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9537 060100, 9537 060250, 9537 060500, 9537 0601000, UPC 612825255291 |