Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 9545 060, 24 40C Stranded TNC SRPVC Foil Shield PVC 300V, Chrome Jacket

Belden 9545 060

SKU:Belden 9545 060

Request a Quote

Request a Quote

Description

Specifications

Belden 9545 060, 24 40C Stranded TNC SRPVC Foil Shield PVC 300V, Chrome Jacket specifications
AttributeValue
Conductor MaterialTC - Tinned Copper
Color CodeBlack, White, Red, Green, Orange, Blue, White/Black Stripe, Red/Black Stripe, Green/Black Stripe, Orange/Black Stripe, Blue/Black Stripe, Black/White Stripe, Red/White Stripe, Green/White Stripe, Blue/White Stripe, Black/Red Stripe, White/Red Stripe, Orange/Red Stripe, Blue/Red Stripe, Red/Green Stripe, Orange/Green Stripe, Black/White/Red Stripes, White/Black/Red Stripes, Red/Black/White Stripes, Green/Black/White Stripes, Orange/Black/White Stripes, Blue/Black/White Stripes, Black/Red/Green Stripes, White/Red/Green Stripes, Red/Black/Green Stripes, Green/Black/Orange Stripes, Orange/Black/Green Stripes, Blue/White/Orange Stripes, Black/White/Orange Stripes, White/Red/Orange Stripes, Orange/White/Blue Stripes, White/Red/Blue Stripes, Black/White/Green Stripes, White/Black/Green Stripes, Red/White/Green Stripes
Shield TypeTape
Shield MaterialBi-Laminate (Alum+Poly)
Insulation thickness (nom.)0.011 in (0.28 mm)
Insulation diameter (nom.)0.044 in (1.1 mm)
Jacket thickness (nom.)0.040 in (1.0 mm)
Overall cable diameter (nom.)0.406 in (10.3 mm)
Bulk cable weight120 lbs/1000ft
Nom. conductor DCR25 Ohm/1000ft
Nom. capacitance cond-to-cond30 pF/ft (98 pF/m)
Nom. capacitance cond-to-other (conds + Shield)55 pF/ft (180 pF/m)
Max. current1.1 Amps per Conductor at 25ºC
Nom. outer shield DCR18 Ohm/1000ft (59 Ohm/km)
UL temperature60°C (UL CMG);80°C (UL AWM 2464)
Operating temperature-30°C to +80°C
Bend radius (stationary min.)4.9 in (120 mm)
Bend radius (installation min.)4.9 in (120 mm)
Max Pull Tension226 lbs (103 kg)
Environmental suitabilityIndoor (Not Riser or Plenum), Indoor
Flammability / reaction to fireUL 1685 FT4 Loading, FT4, IEC 60332-1-2
CPR complianceCPR Euroclass: Eca
NEC / UL complianceArticle 800, CMG
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
European directive complianceEU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Item TypeBelden Multi Conductor Cable
Other Part Numbers9545 060100, 9545 060250, 9545 060500, 9545 0601000, UPC 612825255697
Priced PerFT

Documents

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.