Belden 9546 060, Multi Conductor Computer Cable 50C 24 AWG PVC

SKU:Belden 9546 060
● In stock
Description
Belden 9546 060 is a 50-conductor computer EIA RS-232 cable built with 24 AWG stranded (7x32) TC - tinned copper conductors and SR-PVC - polyvinyl chloride (semi-rigid) insulation. It features an overall Beldfoil® shield with 100% coverage and a 24 AWG (7x32) TC drainwire to help reduce noise in computer communications and low voltage analog or digital control circuits. Finished with a PVC - polyvinyl chloride jacket in Chrome, it supports Article 800, CMG, and AWM 2464.
Belden 9546 060 Key Features
- 50-conductor computer EIA RS-232 cable design for multi-conductor signal and control wiring.
- 24 AWG stranded (7x32) TC - tinned copper conductors for flexible terminations and consistent conductivity.
- SR-PVC - polyvinyl chloride (semi-rigid) insulation to support stable conductor separation.
- Overall Beldfoil® shield with 100% coverage plus a 24 AWG (7x32) TC drainwire to help reduce noise in computer communications and low voltage analog or digital control circuits.
- PVC - polyvinyl chloride jacket in Chrome for identification in installed systems.
- Compliance support: Article 800, CMG, AWM 2464.
Belden 9546 060 Applications
- Commonly used in RS-232 applications where dependable signal transmission is needed.
- Supports computer communications wiring in systems that benefit from noise reduction.
- Suitable for low voltage analog signals (4-20mA, 0-10V, ...) in control and instrumentation circuits.
- Applies to low voltage digital control (24V, …) where stable electrical performance is required.
- Used for line level audio connections where consistent electrical performance is important.
- A practical choice for panel wiring in indoor installations (Not Riser or Plenum).
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket thickness (nom.) | 0.045 in (1.1 mm) |
| Overall cable diameter (nom.) | 0.490 in (12.4 mm) |
| Color Code | Black, White, Red, Green, Orange, Blue, White/Black Stripe, Red/Black Stripe, Green/Black Stripe, Orange/Black Stripe, Blue/Black Stripe, Black/White Stripe, Red/White Stripe, Green/White Stripe, Blue/White Stripe, Black/Red Stripe, White/Red Stripe, Orange/Red Stripe, Blue/Red Stripe, Red/Green Stripe, Orange/Green Stripe, Black/White/Red Stripes, White/Black/Red Stripes, Red/Black/White Stripes, Green/Black/White Stripes, Orange/Black/White Stripes, Blue/Black/White Stripes, Black/Red/Green Stripes, White/Red/Green Stripes, Red/Black/Green Stripes, Green/Black/Orange Stripes, Orange/Black/Green Stripes, Blue/White/Orange Stripes, Black/White/Orange Stripes, White/Red/Orange Stripes, Orange/White/Blue Stripes, White/Red/Blue Stripes, Black/White/Green Stripes, White/Black/Green Stripes, Red/White/Green Stripes, Green/White/Blue Stripes, Orange/Red/Green Stripes, Blue/Red/Green Stripes, Black/White/Blue Stripes, White/Black/Blue Stripes, Red/White/Blue Stripes, Green/Orange/Red Stripes, Orange/Red/Blue Stripes, Blue/Orange/Red Stripes, Black/Orange/Red Stripes |
| Bulk cable weight | 149 lbs/1000ft |
| UL Voltage Rating | 300 V (CMG), 300 V (UL AWM 2464) |
| Conductor DCR (nom.) | 25 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 30 pF/ft (98 pF/m) |
| Capacitance, Cond-to-other (nom.) | 55 pF/ft (180 pF/m) |
| Max. current | 1.1 Amps per Conductor at 25ºC |
| Outer shield DCR (nom) | 18 Ohm/1000ft (59 Ohm/km) |
| Operating temperature | -30°C to +80°C |
| UL temperature | 60°C (UL CMG); 80°C (UL AWM 2464) |
| Stationary min. bend radius | 5.9 in (150 mm) |
| Installation min. bend radius | 5.9 in (150 mm) |
| Max Pull Tension | 281 lbs (127 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9546 060100, 9546 060250, 9546 060500, 9546 0601000, UPC 612825255727 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.