Belden 9554 060, Power Limited Tray Cable 4PR 18 AWG 300V PVC, Chrome Jacket

SKU:Belden 9554 060
● In stock
Description
Belden 9554 060 is an instrumentation Power Limited Tray Cable (PLTC) with 4 twisted pairs of 18 AWG (19x30) TC - Tinned Copper conductors and PVC - Polyvinyl Chloride insulation. It features an overall Beldfoil® shield with 100% coverage and an 18 AWG (7x26) TC drainwire to support noise reduction. The cable is rated 300 V (PLTC, CMG) and 105°C, and it uses a PVC - Polyvinyl Chloride outer jacket in Chrome. Environmental suitability includes Indoor/Outdoor, Sunlight Resistance, and Burial.
Belden 9554 060 Key Features
- 4 pair(s) construction with 18 AWG (19x30) TC - Tinned Copper conductors.
- PVC - Polyvinyl Chloride insulation with ICEA Chart E2 color code.
- Overall Beldfoil® shield (Tape) using Bi-Laminate (Alum+Poly) with 100% coverage, plus an 18 AWG (7x26) TC drainwire.
- PVC - Polyvinyl Chloride outer jacket in Chrome with PP - Polypropylene Tape separator and a ripcord.
- UL voltage rating: 300 V (PLTC, CMG) and UL temperature: 105°C.
- Environmental suitability: Indoor/Outdoor, Sunlight Resistance, Burial.
Belden 9554 060 Applications
- Supports instrumentation circuits in industrial control and process applications where reliable signal transmission is required.
- Connects sensors, valves, and positioners in control systems.
- Works in 4-20mA and 0-10V circuits for instrumentation and control wiring.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 4 |
| Element type | pair(s) |
| Insulation nominal thickness | 0.019 in (0.48 mm) |
| Insulation diameter (nominal) | 0.081 in (2.1 mm) |
| Jacket nominal thickness | 0.053 in (1.3 mm) |
| Overall cable diameter (nominal) | 0.466 in (11.8 mm) |
| Armor | No |
| Bulk cable weight | 113 lbs/1000ft |
| Nom. conductor DCR | 7.2 Ohm/1000ft |
| Nom. outer shield DCR | 4.98 Ohm/1000ft (16.3 Ohm/km) |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 54 pF/ft (180 pF/m) |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Max. current | 3.5 Amps per Conductor at 25ºC |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Bend radius (stationary min.) | 4.7 in (120 mm) |
| Bend radius (installation min.) | 4.7 in (120 mm) |
| Max Pull Tension | 220 lbs (100 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| CPR Euroclass | Eca |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9554 060100, 9554 060250, 9554 060500, 9554 0601000, UPC 612825255833 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.